The accuracy of calculated base excess in blood.

نویسندگان

  • Werner Lang
  • Rolf Zander
چکیده

Most equations used for calculation of the base excess (BE, mmol/l) in human blood are based on the fundamental equation derived by Siggaard-Andersen and called the Van Slyke equation: BE = Z x [[cHCO3-(P) - C7.4 HCO3-(P)] + beta x (pH -7.4)]. In simple approximation, where Z is a constant which depends only on total hemoglobin concentration (cHb, g/dl) in blood, three equations were tested: the ones proposed by Siggaard-Andersen (SA), the National Committee for Clinical Laboratory Standards (NCCLS) or Zander (ZA). They differ only slightly in the solubility factor for carbon dioxide (alphaCO2, mmol/l x mmHg) and in the apparent pK(pK'), but more significantly in the plasma bicarbonate concentration at reference pH (C7.4HCO3-(P), mmol/l) and in beta, the slope of the CO2-buffer line (mmol/l) for whole blood. Furthermore, the approximation was improved either by variation in Z (r(c)), or in the apparent pK (pK) with changing pH. Thus, from a total of seven equations and from a reference set for pH, pCO2 and BE taken from the literature (n=148), the base excess was calculated. Over the whole range of base excess (-30 to +30 mmol/l) and PCO2 (12 to 96 mmHg), mean accuracy (deltaBE, mmol/l) was greatest in the simple equation according to Zander and decreased in the following order: +/-0.86 (ZA); +/-0.94 (ZA, r(c)); +/-0.96 (SA, r(c)); +/-1.03 (NCCLS, r(c)); +/-1.40 (NCCLS); +/-1.48 (SA); and +/-1.50 (pK'). For all clinical purposes, the Van Slyke equation according to Zander is the best choice and can be recommended in the following form: BE= (1 -0.0143 x cHb) x [[0.0304 x PCO2 x 10pH-6.1-24.26] + (9.5+1.63 x cHb) x (pH -7.4)] - 0.2 x cHb x (1-sO2), where the last term is a correction for oxygen saturation (sO2). Hence, base excess can be obtained with high accuracy (<1 mmol/l) from the measured quantities of pH, pCO2, cHb, and SO2 in any sample, irrespective of whether venous or arterial blood is used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The relationship between umbilical artery blood gas analysis and Apgar scores in neonates

  Extended Abstract Introduction and Background : in the first minutes of life it’s important to assess newborn condition very fast but effective and decide about medical intervention as needed. Umbilical artery blood gas analysis and Apgar scoring are the most common assessment systems which studies are trying to more sensitive and accurate way.in this study we compare Apgar scoring system an...

متن کامل

Prediction of Respiratory Morbidities in Late Preterm Neonates Using Cord Blood Arterial Lactate and Base Excess

Background: Late preterm neonates may have the external appearance and behavior similar to their counterparts.However, they are susceptible to various neonatal morbidities , due to their physiological and metabolical immaturity.To assess the correlation between cord blood arterial lactate levels and base excess with the development ofrespiratory distress in late preterm neonat...

متن کامل

تأثیر مدل‌سازی تراک1 در محاسبه خواص موج بلاست ناشی از انفجار ابر هوا- سوخت

In this work the effect of the accuracy of a FAE detonation modeling on the generated blast wave is investigated. First, a one-dimensional numerical simulation with a reduced chemical kinetics of C2H2-O2-Ar, involving 25 elementary reactions, is used as the base model. The properties of the blast calculated with this model is compared with those of simpler models, the similarity solution of Tay...

متن کامل

The Effect of the Type of Hemodialysis Buffer on the QTc Interval in Patients on Chronic Hemodialysis

Background: Identifying the sources of variation in QTc measurements is important for preventing arrhythmias during and after hemodialysis. The present study was designed to determine the correlation between the type of hemodialysis buffer and the changes in QTc interval in patients on chronic hemodialysis. Methods: Fifty-nine patients on chronic hemodialysis who referred in winter 2007 to hemo...

متن کامل

مقایسه گازهای خون بند ناف در نوزادان با و بدون پیچ‌خوردگی بند ناف دور گردن

Background: Entanglement of the umbilical cord around fetal neck has been reported to be associated with birth asphyxia. On the other hand, current evidence suggests that umbilical arterial pH analysis provides the most sensitive reflection of birth asphyxia. In this study we aimed to evaluate and compare the umbilical arterial hydrogen-ion concentration (pH) and to analyze the blood gases of n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 2002