A Second Beam-diagnostic Beamline for the Advanced Light Source*

نویسندگان

  • F. Sannibale
  • D. Baum
چکیده

A second beamline, BL 7.2, completely dedicated to beam diagnostics is being installed at the Advanced Light Source (ALS). The design has been optimized for the measurement of the momentum spread and emittance of the stored beam in combination with the existing diagnostic beamline, BL 3.1. A detailed analysis of the experimental error has allowed the definition of the system parameters. The obtained requirements found a good matching with a simple and reliable system based on the detection of X-ray synchrotron radiation (SR) through a pinhole system. The actual beamline, which also includes a port for visible and infrared SR as well as an X-ray beam position monitor (BPM), is mainly based on the design of two similar diagnostic beamlines at BESSY II. This approach allowed a significant saving in time, cost and engineering effort. The design criteria, including a summary of the experimental error analysis, as well as a brief description of the beamline are presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noise reduction for the infrared beamline at the Advanced Light Source

Significant reductions in the noise of the infrared light have been made at Beamline 1.4.3 infrared source at the Advanced Light Source (ALS). The primary source of vibrational noise has been identified as the water system for the storage ring RF system, which is located near the beamline. Modifications to this system have reduced the noise by an order of magnitude. The dominant source of highe...

متن کامل

Spatial resolution limits for synchrotron-based spectromicroscopy in the mid- and near-infrared.

Spatial resolution tests were performed on beamline 1.4.4 at the Advanced Light Source in Berkeley, CA, USA, a third-generation synchrotron light source. This beamline couples the high-brightness synchrotron source to a Thermo-Electron Continumicrom XL infrared microscope. Two types of resolution tests were performed in both the mid-IR and near-IR. The results are compared with a diffraction-li...

متن کامل

Measurements of Intra-beam Scattering at Low Emittance in the Advanced Light Source

The beam emittance at the interaction point of linear colliders is expected to be strongly influenced by the emittance of the beams extracted from the damping rings. Intra-beam scattering (IBS) potentially limits the minimum emittance of low-energy storage rings, and this effect strongly influences the choice of energy of damping rings [1]. Theoretical analysis suggests that the NLC damping rin...

متن کامل

A beamline for high-pressure studies at the Advanced Light Source with a superconducting bending magnet as the source.

A new facility for high-pressure diffraction and spectroscopy using diamond anvil high-pressure cells has been built at the Advanced Light Source on beamline 12.2.2. This beamline benefits from the hard X-radiation generated by a 6 T superconducting bending magnet (superbend). Useful X-ray flux is available between 5 keV and 35 keV. The radiation is transferred from the superbend to the experim...

متن کامل

مقایسه تأثیر دو مقدار گسیلندگی کم و زیاد بر تابش سنکروترونی و طراحی خطوط باریکه

In this paper, we have discussed about the role of two emittance values suggested for Iranian Light Source Facility (ILSF) (3.278 and 0.476 nm.rad) on different radiation features of the synchrotron light sources (bending magnet, shaker and oscillator) such as spot size, divergence of the beam on light spot, brilliance and important quantities in beamline design such as photon cross-section, op...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003