Modeling and Simulation of Fresh Air System with LHTS and Solar Energy

نویسندگان

  • Wang Lili
  • Zhang Tao
چکیده

State of the research about the technology of solar energy with LHTS (Latent Heat Thermal Storage ) at home and abroad was firstly introduced, and a fresh air system with solar energy and LHTS was then introduced. After that the fuzzy control system of fresh air temperature was studied. Firstly, a mathematical model of the fan coil was built as the controlled plant. Then, a fuzzy controller was designed and applied to control the fresh air temperature with the features of high non-linearity, large disturbance and uncertainty of fresh air system. Finally, the simulation was realized on the mathematical model of the fan coil. It proves that the fuzzy control system has a high accuracy in stability and is able to resist interference. This research will be helpful for fuzzy controller design of the fresh air system. Keywords-Solar Energy; LHTS; Fresh Air; Mathematical model; Simulation; Fuzzy controller

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy Modeling and Simulation including particle technologies within Single and Double Pass Solar Air Heaters

In order to obtain the best performance of the solar air heaters, it is necessary to find optimum performance conditions. The aim of this research paper is to achieve optimum conditions, by comparing single and double pass solar air heaters. Also, a brief review study of various related research works of all scenarios for a single and double pass and packed bed (including particle technologies)...

متن کامل

Application of Solar Thermal Collectors to Improve the Energy Performance of the Fresh Air HVAC Systems

 In the preset study, the performance of a solar assisted heating, ventilation and air conditioning (HVAC) system in an operating theater building was studied. The yearly performances of the existing HVAC system and the system with the added solar collectors were simulated in terms of energy consumption and provided air conditions using a transient system simulation software (TRNSYS). In t...

متن کامل

Performance Study of a Solar Integrated Central Heating System of a Residential Building Using Trnsys- an Hourly Simulation Model (RESEARCH NOTE)

In this investigation, the performance of an existing heating system of a residential building incorporated with an array of solar thermal collectors was studied. For this purpose, transient systems simulation program model was assembled to estimate the hour-by-hour performance of the existing and the system equipped with the solar thermal collectors in terms of the provided space air condition...

متن کامل

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

Sizing of a Packed Bed Storage for Solar Air Heating Systems (TECHNICAL NOTE)

Packed bed units generally, represent the most suitable storage units for air heating solar systems. In these systems the storage unit receives the heat from the collector during the collection period and discharges the heat to the building at the retrieval process. A method for sizing of packedbed storage in an air heating system is represented. The design is based on the K-S curves, which hav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011