A review of standards and statistics used to describe blood glucose monitor performance.
نویسندگان
چکیده
Glucose performance is reviewed in the context of total error, which includes error from all sources, not just analytical. Many standards require less than 100% of results to be within specific tolerance limits. Analytical error represents the difference between tested glucose and reference method glucose. Medical errors include analytical errors whose magnitude is great enough to likely result in patient harm. The 95% requirements of International Organization for Standardization 15197 and others make little sense, as up to 5% of results can be medically unacceptable. The current American Diabetes Association standard lacks a specification for user error. Error grids can meaningfully specify allowable glucose error. Infrequently, glucose meters do not provide a glucose result; such an occurrence can be devastating when associated with a life-threatening event. Nonreporting failures are ignored by standards. Estimates of analytical error can be classified into the four following categories: imprecision, random patient interferences, protocol-independent bias, and protocol-dependent bias. Methods to estimate total error are parametric, nonparametric, modeling, or direct. The Westgard method underestimates total error by failing to account for random patient interferences. Lawton's method is a more complete model. Bland-Altman, mountain plots, and error grids are direct methods and are easier to use as they do not require modeling. Three types of protocols can be used to estimate glucose errors: method comparison, special studies and risk management, and monitoring performance of meters in the field. Current standards for glucose meter performance are inadequate. The level of performance required in regulatory standards should be based on clinical needs but can only deal with currently achievable performance. Clinical standards state what is needed, whether it can be achieved or not. Rational regulatory decisions about glucose monitors should be based on robust statistical analyses of performance.
منابع مشابه
Analytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملNon-invasive Optical Techniques for determination of blood Glucose levels: A Review Article
This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...
متن کاملThe response of plasma glucose, lactate, protein and hematological parameters to osmotic challenge in common carp (Cyprinuscarpio)
Fluctuations in salinity impose stress on the physiology of the exposed fish population and can modify their structure. It has been noted that changes in blood characteristics and plasma levels serve as the primary link between environmental change and physiological response (McCormick, 2001). Ninety healthy adult Cyprinuscarpio (C. carpio) were randomly divided into five groups and kept in sal...
متن کاملA review of portable air cleaner devices: purification processes, performance standards, effectiveness in controlling indoor air pollutants
Background and objective: Indoor air pollutants are among the five most important environmental health risks. In recent years, concerns regarding indoor air in buildings have increased. In this review, studies conducted on portable air cleaners have been investigated. Materials and methods: After determining the keywords and conducting comprehensive searches in the internet databases, taking i...
متن کاملImpact of social capital on employees' job performance of Forensic Medicine Organization
The aim of this study is to investigate the relationship between social capital among employees with their job performance in Tehran's Forensic Medicine Organization. The study population consisted of all the employees of Tehran's Forensic Medicine Organization in 2015 that based on available statistics are 120 employees that because of limited statistical population, sampling has not been done...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2010