Effect of Alveolar Bone Support on Zygomatic Implants – an FEA Study
نویسندگان
چکیده
The objective of this study was to investigate the influence of maxillary alveolar bone on the stress distribution of zygomatic implants. A three-dimensional finite element model was created of half of a skull. Two zygomatic implants were modelled, placed in the skull supported by the zygomatic bone and the maxillary alveolar bone and connected by a fixed bridge. This model was duplicated, and the area of the maxillary alveolar bone supporting the implants was removed. Occlusal and lateral forces were applied to both models and the maximum von Mises stresses were recorded. Higher maximum stresses were noted in the model with no alveolar support. Occlusal stresses were higher than lateral stresses in the model with no alveolar support. Low stresses were noted in the zygomatic bone in both models. In conclusion, maxillary alveolar bone support is beneficial in the distribution of forces for zygomatic implants.
منابع مشابه
Extrasinus zygomatic implants: three year experience from a new surgical approach for patients with pronounced buccal concavities in the edentulous maxilla.
BACKGROUND The surgical protocol for zygomatic fixtures prescribes an intrasinus approach ideally maintaining the sinus membrane intact and the implant body inside the sinus while gaining access to the zygomatic bone. In the presence of a pronounced buccal concavity, the implant head has to be placed far from the alveolar crest in a palatal direction, which results in a bulky bridge constructio...
متن کاملThree-dimensional finite elemental analysis of zygomatic implants in craniofacial structures.
The objective of this study was to analyse stress distribution in craniofacial structures around zygomatic osseointegrated implants. An integrated system for Digital Imaging and Communications in Medicine (DICOM) data were utilized to create a three-dimensional model of craniofacial structures. The amount and distribution of the main stresses were compared using three-dimensional finite element...
متن کاملBiomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects
BACKGROUND The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). MATERIAL AND METHODS A 3-dimensional finite element model of an Aramany class IV defect was created. Three diffe...
متن کاملSafety of zygomatic bone harvesting: a prospective study of 32 consecutive patients with simultaneous zygomatic bone grafting and 1-stage implant placement.
PURPOSE The purpose of this prospective study was to evaluate the safety of zygomatic bone harvesting and to determine whether a particulated zygomatic bone graft can be used simultaneously with 1-stage dental implants to reconstruct resorbed edentulous alveolar ridges. MATERIALS AND METHODS Altogether, 82 dental implants were placed in 32 patients. Particulated bone grafts harvested from the...
متن کاملRehabilitation of a patient with cleft lip and palate with an extremely edentulous atrophied posterior maxilla using zygomatic implants: case report.
OBJECTIVE This case report describes the clinical and surgical management of a patient with a unilateral alveolar cleft and associated extremely atrophied totally edentulous maxilla. METHOD Two zygomatic implants and four endosseous oral implants were placed under general anesthesia in a compromised maxilla to rehabilitate a 33-year-old patient with cleft lip and palate. The two specially des...
متن کامل