Intraoperative colon mucosal oxygen saturation during aortic surgery.
نویسندگان
چکیده
BACKGROUND Colonic ischemia after aortic reconstruction is a devastating complication with high mortality rates. This study evaluates whether Colon Mucosal Oxygen Saturation (CMOS) correlates with colon ischemia during aortic surgery. MATERIALS AND METHODS Aortic reconstruction was performed in 25 patients, using a spectrophotometer probe that was inserted in each patient's rectum before the surgical procedure. Continuous CMOS, buccal mucosal oxygen saturation, systemic mean arterial pressure, heart rate, pulse oximetry, and pivotal intra-operative events were collected. RESULTS Endovascular aneurysm repair (EVAR) was performed in 20 and open repair in 5 patients with a mean age of 75 +/- 10 (+/-SE) years. CMOS reliably decreased in EVAR from a baseline of 56% +/- 8% to 26 +/- 17% (P < 0.0001) during infrarenal aortic balloon occlusion and femoral arterial sheath placement. CMOS similarly decreased during open repair from 56% +/- 9% to 15 +/- 19% (P < 0.0001) when the infrarenal aorta and iliac arteries were clamped. When aortic circulation was restored in both EVAR and open surgery, CMOS returned to baseline values 56.5 +/- 10% (P = 0.81). Mean recovery time in CMOS after an aortic intervention was 6.4 +/- 3.3 min. Simultaneous buccal mucosal oxygen saturation was stable (82% +/- 6%) during aortic manipulation but would fall significantly during active bleeding. There were no device related CMOS measurement complications. CONCLUSIONS Intra-operative CMOS is a sensitive measure of colon ischemia where intraoperative events correlated well with changes in mucosal oxygen saturation. Transient changes demonstrate no problem. However, persistently low CMOS suggests colon ischemia, thus providing an opportunity to revascularize the inferior mesenteric artery or hypogastric arteries to prevent colon infarction.
منابع مشابه
Impact of Intraoperative Events on Cerebral Tissue Oximetry in Patients Undergoing Cardiopulmonary Bypass.
Previous studies showed that decreased cerebral saturation during cardiac surgery is related to adverse postoperative outcome. Therefore, we investigated the influence of intraoperative events on cerebral tissue saturation in patients undergoing cardiac surgery with cardiopulmonary bypass (CPB). A total of 52 adult patients who underwent cardiac surgery using pulsatile CPB were included in this...
متن کاملThe effect of optimising cerebral tissue oxygen saturation on markers of neurological injury during coronary artery bypass graft surgery.
BACKGROUND Surgical revascularisation of the coronary arteries is a cornerstone of cardiothoracic surgery. Advanced age and the incidence of preoperative co-morbidity in patients presenting for coronary artery bypass graft surgery increases the potential for stroke and other perioperative outcomes. It is hypothesised that by using interventions during cardiac surgery to improve cerebral oxygena...
متن کاملNoninvasive cerebral oxygenation may predict outcome in patients undergoing aortic arch surgery.
OBJECTIVES Surgical repair of the aortic arch remains technically challenging and is associated with considerable morbidity and mortality. Cerebral oximetry is a noninvasive technology that can monitor the regional oxygen saturation of the frontal cortex. We hypothesized that magnitude and duration of decreased intraoperative regional oxygen saturation was associated with postoperative organ dy...
متن کاملEpidural analgesia with bupivacaine does not improve splanchnic tissue perfusion after aortic reconstruction surgery.
Inadequate splanchnic tissue perfusion is relatively common during and after aortic surgery. We hypothesized that vasodilation caused by thoracic epidural analgesia improves splanchnic blood flow and tissue perfusion after aortic surgery. In this prospective, randomized, controlled study, we studied 20 patients undergoing elective aortic-femoral or aortic-iliac reconstruction surgery. Gastric a...
متن کاملContinuous monitoring of mixed venous oxygen saturation during aortic surgery.
The correlation between mixed venous oxygen saturation (SvO2) and hemodynamic measurements was studied in 13 patients undergoing descending thoracic aortic aneurysm resection (DTAAR). A significant correlation (p less than 0.05) was found between cardiac index (CI) and SvO2 after the induction of anesthesia and at the end of surgery. However, no significant correlation could be found between Sv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of surgical research
دوره 136 1 شماره
صفحات -
تاریخ انتشار 2006