Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry

نویسندگان

  • Jinhai Huang
  • Colm McAlinden
  • Yingying Huang
  • Daizong Wen
  • Giacomo Savini
  • Ruixue Tu
  • Qinmei Wang
چکیده

A meta-analysis to compare ocular biometry measured by optical low-coherence reflectometry (Lenstar LS900; Haag Streit) and partial coherence interferometry (the IOLMaster optical biometer; Carl Zeiss Meditec). A systematic literature search was conducted for articles published up to August 6th 2015 in the Cochrane Library, PubMed, Medline, Embase, China Knowledge Resource Integrated Database and Wanfang Data. A total of 18 studies involving 1921 eyes were included. There were no statistically significant differences in axial length (mean difference [MD] 0 mm; 95% confidence interval (CI) -0.08 to 0.08 mm; p = 0.92), anterior chamber depth (MD 0.02 mm; 95% CI -0.07 to 0.10 mm; p = 0.67), flat keratometry (MD -0.05 D; 95% CI -0.16 to 0.06 D; p = 0.39), steep keratometry (MD -0.09 D; 95% CI -0.20 to 0.03 D; p = 0.13), and mean keratometry (MD -0.15 D; 95% CI -0.30 to 0.00 D; p = 0.05). The white to white distance showed a statistically significant difference (MD -0.14 mm; 95% CI -0.25 to -0.02 mm; p = 0.02). In conclusion, there was no difference in the comparison of AL, ACD and keratometry readings between the Lenstar and IOLMaster. However the WTW distance indicated a statistically significant difference between the two devices. Apart from the WTW distance, measurements for AL, ACD and keratometry readings may be used interchangeability with both devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral Low Coherence Interferometry: A Complete Analysis of the Detection System and the Signal Processing

Low coherence interferometry (LCI) is an optical technique in which light is used as an instrument to obtain high resolution optical images in a great diversity of materials. It is possible to find in the literature, a variety of configurations with different names, based on the same principle: low coherence reflectometry (OLCR), optical coherence tomography (OCT), white light interferometry (W...

متن کامل

Comparison of a new optical biometer and a standard biometer in cataract patients

BACKGROUND Cataract surgery is the most common surgical procedure in ophthalmology. Biometry data and accurate intraocular lens (IOL) calculations are very important in achieving the desired refractive outcomes. The aim of this study was to compare measurements using a new optical low coherence reflectometry (OLCR) biometer (OA-2000) and the gold standard partial coherence interferometry (PCI) ...

متن کامل

Phase Noise Considerations in Coherent Optical FMCW Reflectometry

phase noise, coherent reflectometry, FMCW, Rayleigh backscattering, fiberoptic interferometry An analysis of coherent optical FMCW is presented. It shows the limitations imposed on measurements of discrete reflections and of Rayleigh backscattering due to phase noise originating in the finite coherence length of the optical source. The dependence of the range for accurate measurements on partic...

متن کامل

Partial Coherence Laser Interferometry in Highly Myopic versus Emmetropic Eyes

PURPOSE To investigate the reliability of partial coherence laser interferometry for optical biometry in highly myopic eyes. METHODS Axial length measurements by the IOLMaster (Carl Zeiss Meditec, Germany) with signal-to-noise ratio (SNR) ≥2 were performed in 52 consecutive myopic subjects with axial length ≥26.5 mm and 45 emmetropic patients before cataract surgery. Axial length measurements...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017