The factors limiting the diagnostic accuracy of myocardial perfusion cardiac magnetic resonance imaging: coronary flow reserve and amount of myocardial scar

نویسندگان

  • Masaki Ishida
  • Shingo Kato
  • Nanaka Ishida
  • Motonori Nagata
  • Kakuya Kitagawa
  • Hiroshi Nakajima
  • Shiro Nakamori
  • Hajime Sakuma
چکیده

Background Perfusion cardiac magnetic resonance (CMR) imaging has emerged as an important clinical tool for the accurate detection of myocardial ischemia caused by significant coronary artery disease (CAD), whereas most previous studies demonstrated the diagnostic accuracy of perfusion CMR in a highly selected patient population such as those without previous myocardial infarction or lower ejection fraction (EF) etc. In the real clinical practice, however, we may encounter the patients with multiple factors affecting the accurate CMR myocardial perfusion assessment. The aim of this study was to identify the factors reducing the sensitivity of perfusion CMR for predicting significant CAD determined by the coronary angiography (CAG).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Incremental value of cardiac magnetic resonance with adenosine stress perfusion in coronary artery disease detection

Background A multiple-test strategy in often needed in the evaluation of patients (pts) with suspected coronary artery disease (CAD). Cardiac magnetic resonance (CMR) has potential advantages in this context allowing simultaneous evaluation of ventricular function, myocardial perfusion and scar detection with high spatial resolution and no ionizing radiation exposure. We aimed to compare the di...

متن کامل

Validation of dynamic three-dimensional whole heart magnetic resonance myocardial perfusion imaging at 3.0 Tesla against fractional flow reserve for the detection of flow-limiting coronary heart disease

We demonstrate the feasibility of 3D myocardial perfusion CMR at 3 Tesla against fractional flow reserve (FFR) in 53 patients for the detection of flow-limiting coronary artery disease and show good agreement between the techniques. This technique shows excellent diagnostic sensitivity and specificity and may offer an alternative method of detecting ischaemia for the purpose of guiding revascul...

متن کامل

Diagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease

Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...

متن کامل

Whole-heart dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve: determination of volumetric myocardial ischaemic burden and coronary lesion location.

AIMS Dynamic three-dimensional-cardiac magnetic resonance (3D-CMR) perfusion proved highly diagnostic for the detection of angiographically defined coronary artery disease (CAD) and has been used to assess the efficacy of coronary stenting procedures. The present study aimed to relate significant coronary lesions as assessed by fractional flow reserve (FFR) to the volume of myocardial hypoenhan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012