Four methods for identification of gram-negative nonfermenting rods: organisms more commonly encountered in clinical specimens.

نویسندگان

  • P C Appelbaum
  • J Stavitz
  • M S Bentz
  • L C von Kuster
چکیده

Four commercial kits, Oxi/Ferm (OF), API 20E (AP), Minitek (MT; BBL Microbiology Systems), and Flow N/F (NF), were evaluated, without additional tests, for identification of 258 gram-negative nonfermentative rods. OF and MT were read after 48 h of incubation, and AP and NF were read after both 24 and 48 h of incubation, respectively. Overall, OF correctly identified 51% of strains, with 46% as part (but not first) of a spectrum of identifications (SI), and 3% incorrect species identification. MT yielded 85% correct identification, with 15% SI. Of 126 glucose-positive strains, or those with greater than or equal to 3 positive AP reactions after 24 h, 60% were correctly identified, with 40% SI; incubation for an additional 24 h raised the rate of correct identification to 99%, with 1% SI. A total of 132 strains yield less than 3 positive AP reactions after 24 h and were identified after 48 h only; of these, 82% were correctly identified, with 17% SI and 1% incorrect species identification. NF correctly identified 79% of cultures after 24 h, with 21% SI; corresponding figures after an additional 24 h of incubation were 80% and 20%, respectively. All four commercial methods show promise; OF is easiest to inoculate, but requires extra tests for optimal identification. AP reliably identifies the majority of clinically important nonfermenters, with fairly good species identification of saccharolytic strains after 24 h. MT yields reliable identification of most nonfermenters and has the advantage of flexibility. NF is easy to inoculate, yields satisfactory identification rates, and may be read after 24 h of incubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biochemical and susceptibility tests useful for identification of nonfermenting gram-negative rods.

Six hundred nineteen strains of nonfermenting gram-negative rods were tested for alkaline phosphatase, benzyl-arginine arylamidase, pyrrolidonyl arylamidase, ethylene glycol acidification, and susceptibility to desferrioxamine and colistin. The results were highly discriminant. Therefore, the proposed tests may be helpful for the identification of this group of organisms.

متن کامل

Evaluation of two rapid methods for identification of commonly encountered nonfermenting or oxidase-positive, Gram-negative rods.

The ability of the expanded API-20E and the Oxi-Ferm System to identify 176 isolates of nonfermenting or oxidase-positive, gram-negative rods from 17 species or groups was studied. The expanded API-20E, without referral to a computer reference center, was able to identify 61.4% of the isolates to the species level. If reference to the computer center was utilized, an additional 25% could be ide...

متن کامل

Critical evaluation of the AutoMicrobic system gram-negative identification card for identification of glucose-nonfermenting gram-negative rods.

During a 6-month study we critically evaluated the accuracy of the AutoMicrobic system Gram-Negative Identification Card (Vitek Systems, Inc., Hazelwood, Mo.) in identifying glucose-nonfermenting gram-negative bacilli by testing 419 selected isolates in parallel with a conventional reference method. Of 356 isolates included in the AutoMicrobic system profile, a total of 307 (86.2%) were correct...

متن کامل

Validation of Vitek 2 nonfermenting gram-negative cards and Vitek 2 version 4.02 software for identification and antimicrobial susceptibility testing of nonfermenting gram-negative rods from patients with cystic fibrosis.

Accurate identification and antimicrobial susceptibility testing (AST) of nonfermenters from cystic fibrosis patients are essential for appropriate antimicrobial treatment. This study examined the ability of the newly designed Vitek 2 nonfermenting gram-negative card (NGNC) (new gram-negative identification card; bioMérieux, Marcy-l'Etoile, France) to identify nonfermenting gram-negative rods f...

متن کامل

Polyclonal bacteremia due to gram-negative rods.

The frequency of, risk factors for, and outcome of polyclonal gram-negative bacteremia are still unknown. We investigated them in a prospective cohort study of patients for whom a blood culture yielded >/=1 species of gram-negative aerobic rod. For each patient, pulsed field gel electrophoresis (PFGE) was performed on 4 colonies of each morphologic type. Episodes of bacteremia were considered p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 1980