Results from the Vicarious Calibration of ADEOS/AVNIR and the Visible and Near-Infrared Channels of OCTS with AVIRIS
نویسنده
چکیده
A field campaign for the vicarious calibration of the instruments ADEOS/AVNIR (Advanced Earth Observing Satellite/Advanced Visible and Near-Infrared Radiometer) and the visible to near-infrared channels of the Ocean Color and Temperature Scanner (OCTS) was conducted based on the reflectance-based method. The results show a not so small difference between the estimated top of atmosphere (ToA) radiance and the instruments’ data-derived radiance, i.e., 3.5 to 20%. In order to confirm the validity of the difference, vicarious calibration based on the radiance-based method was conducted using Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data. Also, an effect due to the spectral refractive index of aerosol on the estimation of the ToA radiance was confirmed, together with smear-like image defect in the AVNIR imagery data.
منابع مشابه
Vicarious Calibration Based Cross Calibration of Solar Reflective Channels of Radiometers Onboard Remote Sensing Satellite and Evaluation of Cross Calibration Accuracy through Band-to-Band Data Comparisons
Accuracy evaluation of cross calibration through band-to-band data comparison for visible and near infrared radiometers which onboard earth observation satellites is conducted. The conventional cross calibration for visible to near infrared radiometers onboard earth observation satellites is conducted through comparisons of band-to-band data of which spectral response functions are overlapped m...
متن کاملRadiometric Measurement Comparison Using the Ocean Color Temperature Scanner (OCTS) Visible and Near Infrared Integrating Sphere
As a part of the pre-flight calibration and validation activities for the Ocean Color and Temperature Scanner (OCTS) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) ocean color satellite instruments, a radiometric measurement comparison was held in February 1995 at the NEC Corporation in Yokohama, Japan. Researchers from the National Institute of Standards and Technology (NIST), the Nat...
متن کاملComparison Among Cross, Onboard and Vicarious Calibrations for Terra/ASTER/VNIR
Comparative study on radiometric calibration methods among onboard, cross and vicarious calibration for visible to near infrared radiometers onboard satellites is conducted. The data sources of the aforementioned three calibration methods are different and independent. Therefore, it may say that the reliable Radiometric Calibration Accuracy: RCC would be the RCC which are resemble each other tw...
متن کاملCal/Val Results and Accuracy Assessment Plan for PRISM and AVNIR-2 Onboard ALOS
This paper introduces the updated results of calibration for optical instruments of the Advanced Land Observing Satellite (ALOS, nicknamed “Daichi”), was successfully launched on January 24th, 2006, and it continuously working very well. ALOS has three mission instruments; an L-band Synthetic Aperture Radar called PALSAR, and two optical sensors called PRISM and AVNIR-2. PRISM stands for the Pa...
متن کاملPrediction of Freshness Quality and Phosphate Residue of White Shrimp Products Using Near-Infrared Spectroscopy
Background: The manufacturing of frozen shrimp is an important industry for the economy of Thailand. The objective of this study was to use Near-Infrared (NIR) spectroscopy to determine the freshness quality, including Total Volatile Basic Nitrogen (TVB-N) and Water Holding Capacity (WHC) of white shrimp (whole and chopped shrimp) and phosphate residues of shrimp. Methods: Sixty white shrimp ...