Cost Analysis of Using a Closed-System Transfer Device (CSTD) for Antineoplastic Drug preparation in a Malaysian Government-Funded Hospital

نویسندگان

  • Huan Keat Chan
  • Yik Ming Lim
چکیده

Background: Apart from reducing occupational exposure to cytotoxic hazards, the PhaSeal® closed-system transfer device (CSTD) can extend the beyond-use dates (BUDs) of unfinished vials of antineoplastic drugs for up to 168 hours (seven days). In this study, the total material cost incurred by its use in a Malaysian government-funded hospital was calculated. Methods: A list of vial stability following initial needle punctures of 29 commonly-used antineoplastic drugs was compiled. The amount of the materials used, including drugs, infusion bottles, the PhaSeal® CSTD and other consumables, was recorded on a daily basis for three months in 2015. The total cost was calculated based on the actual acquisition costs, and was compared with that of a hypothetical scenario, whereby conventional syringe-needle sets were used for the same amounts of preparations. Results: The use of the PhaSeal® CSTD incurred a cost of MYR 383,634.52 (USD 92,072.28) in three months, representing an average of MYR 170.5 (USD 40.92) per preparation or an estimated annual cost of MYR 1,534,538.08 (USD 368,289.14). Compared with conventional syringe-needle approach, it is estimated to lead to an additional spending of MYR 148,627.68 (USD 35,670.64) yearly. Conclusion: Although there was a reduction of drug wastage achieved by extending BUDs of unfinished vials using the PhaSeal® CSTD, cost saving was not observed, likely attributable to the wide use of lower-priced generic drugs in Malaysia. Future studies should further evaluate the possibility of cost saving, especially in health settings where branded and high-cost antineoplastic drugs are more commonly used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A summary of the published clinical evidence of the effectiveness of the BD PhaSeal closed-system drug transfer device (CSTD)

Purpose. The primary objective of this study was to compare the levels of environmental contamination before and after the introduction of PhaSeal (closed-system drug transfer device) in two hospital pharmacies. Our secondary objective was to assess the impact of the device on the duration of drug preparation compared to procedures involving the use of needles and syringes. Methods. The study i...

متن کامل

Effectiveness of a Closed-System Transfer Device in Reducing Surface Contamination in a New Antineoplastic Drug-Compounding Unit: A Prospective, Controlled, Parallel Study

BACKGROUND The objective of this randomized, prospective and controlled study was to investigate the ability of a closed-system transfer device (CSTD; BD-Phaseal) to reduce the occupational exposure of two isolators to 10 cytotoxic drugs and compare to standard compounding devices. METHODS AND FINDINGS The 6-month study started with the opening of a new compounding unit. Two isolators were se...

متن کامل

Healthcare Services Quality in Malaysian Private Hospitals: A Qualitative Study

Background and objectives: Services quality has become the major concern of policy-makers in the present rapidly growing consumer-oriented health industry. However, there is a major gap in the relevant literature in Malaysia in this particular field. Thus, this research attempted to narrow this gap by conducting a qualitative study to gain insight into quality of healthcare services in the Mala...

متن کامل

Impact of economic sanctions on orthopedic residency program (education & training)

Several factors are associated with residency programs (1). For the assessment process of the residency program, applicants’ official transcripts, curriculum vitae, personal letters, references, and performance at interviews are usually used (1). Orthopedic residency selection is affected by program and staff reputation as well as by hospital facilities provided by the institution (1). Social a...

متن کامل

Use of a closed system device to reduce occupational contamination and exposure to antineoplastic drugs in the hospital work environment.

OBJECTIVES The aim of the preset study was to evaluate the applicability of a closed system device to protect against occupational contamination and exposure to antineoplastic drugs in the work environment of a hospital. METHODS We compared the contamination by and exposure to cyclophosphamide (CPA) between a conventional mixing method and a mixing method using a closed system device. Wipe sa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016