Accuracy of urine dipsticks, 2-h and 12-h urine collections for protein measurement as compared with the 24-h collection.
نویسندگان
چکیده
The presence of protein in hypertensive disorders of pregnancy is a sign of a worsening condition and thus requires early intervention to prevent adverse consequences. Accurate assessment of proteinuria in patients with pre-eclampsia will ensure prompt and timely intervention to reduce or prevent the maternal and perinatal morbidity and mortality associated with pre-eclampsia. This study compared the reliability and validity of the more rapid diagnostic tests, such as the dipstick, 2-h and 12-h protein estimations with the 24-h protein. The result of the dipstick, 2-h and 12-h urine were also compared with the 24-h urine results using confidence interval (CI) for proportions with a value of p < 0.05 considered significant (CI 95%). When compared with the gold standard, there was a high degree of correlation between the 2-h (p = 0.244, CI 95%) and 12-h (p < 0.0255, CI 95%) with the 24-h sample in the quantification of proteinuria in women with pre-eclampsia. The most sensitive and specific test was the 12-h protein estimation, (89%) and (93%), respectively. The least sensitive and specific test was the dipstick test; (81%) and (47%), respectively. The 12-h protein estimation test had the highest positive predictive value (84%). The 12-h protein test also had the lowest false positive rate (12%) and false negative rates (11%), respectively. The most accurate test was the 12-h protein estimation (88%). The dipstick tests were however much cheaper and the results were faster. It is recommended that routine rapid quantisation of proteinuria in patients with pre-eclampsia be done using either the 2-h or 12-h urine sample.
منابع مشابه
مقایســه اندازهگیری سطح آلبومین به روش ایمونوتوربیدومتری در ســه شیوه مختلف نـمونهگیری ادراری برای غربالگری آلبومینوری در بیماران دیابتی
Background: Microalbominuria (MA) is early presentation of renal damage which acts as an independent factor of cardiovascular events in these patients. There are various methods for sampling and also different laboratory tests to measuring albominuria. The aim of this study was to compare of different urine collection methods for measuring albominuria using immunoturbidometry assay which has a...
متن کاملReplacing 24-h Albumin Excretion with a Shorter Collection Period in Preeclampsia.
OBJECTIVES To evaluate whether the gold standard of 24-h urinary albumin excretion in preeclamptic women could be substituted by a shorter collection period. METHODS From each woman, three spot, two 12-h, and one 24-h urine samples were collected. For each sample, urine albumin concentrations in milligram per liter were analyzed by the immunoturbidimetric method. The albumin concentrations in...
متن کاملCollection and handling of 24-hour urine specimens for measurement of analytes related to renal calculi.
Analysis for calcium, magnesium, phosphorus, oxalate, uric acid, and creatinine in 24-h urine collections is often needed for the differential diagnosis of patients with renal calculi. Considerable attention has been given to improving the methods of analysis, but improper sample collection and processing can cause significant errors for calcium and oxalate in urine samples not treated with aci...
متن کاملEvaluation of 8-hour and 12-hour urine collection for detection of proteinuria in hypertensive women, Shariati hospital, 2004 - 2005
Introduction: Hypertensive disorders are common during pregnancy. Combination of hypertension and proteinuria markedly increase prenatal morbidity and mortality. The gold standard method for proteinuria assessment is 24-hour urine collection. This survey is designed to determine the correlation between protein content of 8-hour and 24-hour urine collections. Methods: This cross-sectional study...
متن کامل24-Hour Urine Samples Are More Reproducible Than Spot Urine Samples for Evaluation of Iodine Status in School-Age Children.
BACKGROUND Variation in different urinary measurements for evaluation of iodine status is of concern to clinicians and researchers. OBJECTIVE This study evaluated variations between urine iodine concentration (UIC), spot and 24-h urine sample creatinine concentrations, and 24-h urine iodine excretion (24-h UIE) in repeated samples from school-age children. METHODS Urine samples (24 h and mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of obstetrics and gynaecology : the journal of the Institute of Obstetrics and Gynaecology
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2008