Absolute efficiency and time-response measurement of single-photon detectors.

نویسندگان

  • P G Kwiat
  • A M Steinberg
  • R Y Chiao
  • P H Eberhard
  • M D Petroff
چکیده

Using correlated photons from spontaneous parametric downconversion, we have measured both the absolute quantum efficiencies and the time responses of four single-photon detectors. Efficiencies as high as (76.4 ± 2.3)% (at 702 nm) were seen, which to our knowledge are the highest reported single-photon detection efficiencies. An auxiliary retroreflection mirror was found to increase the net detection efficiency by as much as a factor of 1.19. The narrowest time profile for coincidences between two detectors displays a peak with 300 ps FWHM. We also investigated the presence of afterpulses and the effects of saturation and varying device parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conceptual Design and Simulation of Alpha-Beta Detector for Surface Contamination Measurements

The radioactive contamination measurement is essential in nuclear facilities. Monitoring of low level alpha and beta contamination is possible using light detectors high efficiency. Due to the fact that many detectors canchr('39')t simultaneously discriminate alpha, beta and gamma rays; among existing methods, phoswich detectors would be appropriate option to measure different radioactive conta...

متن کامل

Measurement of quantum efficiency using correlated photon pairs and a single-detector technique

A new approach is proposed to the calibration of photodetectors and the determination of the absolute value of the quantum efficiency of photon-counting photomultipliers using entangled-photon pairs. It is based on a new single-photodetector technique and a special modulation of the entangled-photon flux. The absolute values of the quantum efficiency have been determined for several photon-coun...

متن کامل

Absolute efficiency estimation of photon-number-resolving detectors using twin beams.

A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brig...

متن کامل

Autonomous absolute calibration of an ICCD camera in single-photon detection regime.

Intensified charge coupled device (ICCD) cameras are widely used in vari-ous applications such as microscopy, astronomy, spectroscopy. Often they are used as single-photon detectors, with thresholding being an essential part of the readout. In this paper, we measure the quantum efficiency of an ICCD camera in the single-photon de-tection mode using the Klyshko absolute calibration technique. Th...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 33 10  شماره 

صفحات  -

تاریخ انتشار 1994