Lung volume changes during cleaning of closed endotracheal suction catheters: a randomized crossover study using electrical impedance tomography.
نویسندگان
چکیده
BACKGROUND Airway suctioning in mechanically ventilated patients is required to maintain airway patency. Closed suction catheters (CSCs) minimize lung volume loss during suctioning but require cleaning post-suction. Despite their widespread use, there is no published evidence examining lung volumes during CSC cleaning. The study objectives were to quantify lung volume changes during CSC cleaning and to determine whether these changes were preventable using a CSC with a valve in situ between the airway and catheter cleaning chamber. METHODS This prospective randomized crossover study was conducted in a metropolitan tertiary ICU. Ten patients mechanically ventilated via volume-controlled synchronized intermittent mandatory ventilation (SIMV-VC) and requiring manual hyperinflation (MHI) were included in this study. CSC cleaning was performed using 2 different brands of CSC (one with a valve [Ballard Trach Care 72, Kimberly-Clark, Roswell, Georgia] and one without [Portex Steri-Cath DL, Smiths Medical, Dublin, Ohio]). The maneuvers were performed during both SIMV-VC and MHI. Lung volume change was measured via impedance change using electrical impedance tomography. A mixed model was used to compare the estimated means. RESULTS During cleaning of the valveless CSC, significant decreases in lung impedance occurred during MHI (-2563 impedance units, 95% CI 2213-2913, P < .001), and significant increases in lung impedance occurred during SIMV (762 impedance units, 95% CI 452-1072, P < .001). In contrast, cleaning of the CSC with a valve in situ resulted in non-significant lung volume changes and maintenance of normal ventilation during MHI and SIMV-VC, respectively (188 impedance units, 95% CI -136 to 511, P = .22; and 22 impedance units, 95% CI -342 to 299, P = .89). CONCLUSIONS When there is no valve between the airway and suction catheter, cleaning of the CSC results in significant derangements in lung volume. Therefore, the presence of such a valve should be considered essential in preserving lung volumes and uninterrupted ventilation in mechanically ventilated patients.
منابع مشابه
Effect of closed endotracheal tube suction method, catheter size, and post-suction recruitment during high-frequency jet ventilation in an animal model.
RATIONALE High-frequency jet ventilation (HFJV) is often used to treat infants with pathologies associated with gas trapping and abnormal lung mechanics, who are sensitive to the adverse effects of suction. OBJECTIVE This study aimed to investigate the effect of closed suction (CS), catheter size, and the use of active post-suction sighs on tracheal pressure (P(trach)), and global and regiona...
متن کاملThe use of a novel cleaning closed suction system reduces the volume of secretions within the endotracheal tube as assessed by micro-computed tomography: a randomized clinical trial.
BACKGROUND Early after intubation, a layer of biofilm covers the inner lumen of the endotracheal tube (ETT). Cleaning the ETT might prevent airways colonization by pathogens, reduce resistance to airflow, and decrease sudden ETT obstruction. We investigated the effectiveness of a cleaning closed suction system in maintaining the endotracheal tube free from secretions. METHODS We conducted a s...
متن کاملSide effects of endotracheal suction in pressure- and volume-controlled ventilation.
STUDY OBJECTIVES To investigate the effects of endotracheal suction in volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) with an open suction system (OSS) or a closed suction system (CSS). DESIGN Randomized comparison. SETTING Animal research laboratory. PATIENTS Twelve healthy anesthetized pigs. INTERVENTIONS The effects of endotracheal suction during VCV an...
متن کاملComparison of the Effects of Open and Closed Endotracheal Suction on Cardiovascular and Ventilation Parameters for Patients Undergoing Mechanical Ventilation
Background and Objectives: Suction is a necessary and common method which aids in the release of secretion from the respiratory system for the patients who have undergone mechanical ventilation. One of the most common complications of suction is hypoxemia which causes dysrhythmia and death. The purpose of this study was to determine the effects of open and closed-endotracheal suction on cardiov...
متن کاملRepeated open endotracheal suctioning causes gradual desaturation but does not exacerbate lung injury compared to closed endotracheal suctioning in a rabbit model of ARDS
BACKGROUND Although endotracheal suctioning induces alveolar derecruitment during mechanical ventilation, it is not clear whether repeated endotracheal suctioning exacerbates lung injuries. The present study aimed to determine whether repeated open endotracheal suctioning (OS) exacerbates lung injury compared to closed endotracheal suctioning (CS) during mechanical ventilation in an animal mode...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 59 4 شماره
صفحات -
تاریخ انتشار 2014