The human patellar tendon moment arm assessed in vivo using dual-energy X-ray absorptiometry.

نویسندگان

  • Robert M Erskine
  • Christopher I Morse
  • Stephen H Day
  • Alun G Williams
  • Gladys L Onambele-Pearson
چکیده

Accurate assessment of muscle-tendon forces in vivo requires knowledge of the muscle-tendon moment arm. Dual-energy X-ray absorptiometry (DXA) can produce 2D images suitable for visualising both tendon and bone, thereby potentially allowing the moment arm to be measured but there is currently no validated DXA method for this purpose. The aims of this study were (i) to compare in vivo measurements of the patellar tendon moment arm (dPT) assessed from 2D DXA and magnetic resonance (MR) images and (ii) to compare the reliability of the two methods. Twelve healthy adults (mean ± SD: 31.4 ± 9.5 yr; 174.0 ± 9.5 cm; 76.2 ± 16.6 kg) underwent two DXA and two MR scans of the fully extended knee at rest. The tibiofemoral contact point (TFCP) was used as the centre of joint rotation in both techniques, and the dPT was defined as the perpendicular distance from the patellar tendon axis to the TFCP. The dPT was consistently longer when assessed via DXA compared to MRI (+3.79 ± 1.25 mm or +9.78 ± 3.31%; P<0.001). The test-retest reliability of the DXA [CV=2.13%; ICC=0.94; ratio limits of agreement (RLA)=1.01 (*/÷1.07)] and MR [(CV=2.27%; ICC=0.96; RLA=1.00 (*/÷1.07)] methods was very high and comparable between techniques. Moreover, the RLA between the mean DXA and MRI dPT values [1.097 (*/÷1.061)] demonstrated very strong agreement between the two methods. In conclusion, highly reproducible dPT measurements can be determined from DXA imaging with the knee fully extended at rest. This has implications for the calculation of patellar tendon forces in vivo where MR equipment is not available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes of the Patellar Tendon Moment arm Length in Different Knee Angles: A Biomechanical in Vivo Study

Patellar tendon moment arm length (PTma) changes at different knee flexion angles have not been determined in invivo studies. We aimed to determine PTma in four different knee angles using Magnetic Resonance Imaging (MRI) topredict in vivo changes in the moment arm length from different knee angles during running.PTma was measured as the perpendicular distance from muscle–tend...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Monte Carlo Modeling of Dual and Triple Photon Energy Absorptiometry Technique

Introduction: Osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. The affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures.  A timely and accurate diagnosis of this disea...

متن کامل

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

Assessment of bone mineral density with dual energy X-ray absorptiometry in pre- and post-menopausal women

Background: Osteoporosis is a chronic disease that contributes substantially to decrease physical activity and decline in the quality of life. Osteoporosis can be diagnosed easily with the use of dual-energy X-ray absorptiometry (DXA) equipment. The aim of this study was to investigate the magnitude of bone loss on proximal femur and lumbar spine LS in pre- and post-menopausal women f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 47 6  شماره 

صفحات  -

تاریخ انتشار 2014