Onset mechanism of paroxysmal atrial fibrillation detected by ambulatory Holter monitoring.
نویسندگان
چکیده
AIMS The aim of this study was to evaluate the mechanisms of induction of paroxysmal atrial fibrillation (PAF) by analysis of its onset recorded on Holter monitoring (HM). METHODS AND RESULTS One hundred and seven HM were evaluated in 90 patients (mean age 67.7, cardiac disease in 31.1%), with one or more self-terminating episodes of PAF, lasting >or=30 s. Two hundred and thirty-three episodes of PAF were detected. A triggering premature atrial complex (PAC) was present in 222/233 episodes (95.3%); 118/233 episodes were preceded by a bradyarrhythmic event (BE) or a post-extrasystolic pause (50.6%). According to the polarity of the ectopic P-wave, triggering PACs were left atrial origin in 74.3%, right atrial in 15.3%, not determined in 10.4% of cases. Coupling interval (CI) of triggering PACs was shorter in episodes preceded by BEs; it was shorter than that of non-triggering PACs. Frequency of PACs was significantly higher in the hour preceding the onset of PAF. During the day, three periods of higher frequency of PAF onsets were found from noon to 2 p.m., 6 p.m. to 2 a.m., and 4 a.m. to 6 a.m. Heart rate variability analysis showed a vagal prevalence in the 5 min preceding the onset of arrhythmia, both in the time and in the frequency domain. CONCLUSION Paroxysmal atrial fibrillation is generally triggered by a PAC, with left atrial origin in two-thirds of cases: CI and neuroendocrine balance are factors affecting the induction of the arrhythmia.
منابع مشابه
Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke.
BACKGROUND AND PURPOSE Cardioembolism in paroxysmal atrial fibrillation (pxAF) is a frequent cause of ischemic stroke. Sensitive detection of pxAF after stroke is crucial for adequate secondary stroke prevention; the optimal diagnostic modality to detect pxAF on stroke units is unknown. We compared 24-hour Holter electrocardiography (ECG) with continuous stroke unit ECG monitoring (CEM) for pxA...
متن کاملUtility of Duranta, a wireless patch-type electrocardiographic monitoring system developed in Japan, in detecting covert atrial fibrillation in patients with cryptogenic stroke
RATIONALE Subcutaneous implantable electrocardiographs are highly effective in detecting covert atrial fibrillation (AF) in cryptogenic stroke. However, these invasive devices are not indicated for all cryptogenic stroke patients, and noninvasive improvements over conventional Holter-type ambulatory electrocardiography are needed. We evaluated the clinical application and effectiveness of Duran...
متن کاملUse of a Noninvasive Continuous Monitoring Device in the Management of Atrial Fibrillation: A Pilot Study
BACKGROUND Outpatient ambulatory cardiac rhythm monitoring is a routine part of the management of patients with paroxysmal atrial fibrillation (AF). Current systems are limited by patient convenience and practicality. METHODS We compared the Zio(®) Patch, a single-use, noninvasive waterproof long-term continuous monitoring patch, with a 24-hour Holter monitor in 74 consecutive patients with p...
متن کاملPredicting Intermittent Atrial Fibrillation in Outpatient Clinics
BACKGROUND AND OBJECTIVES Palpitations are the most common complaint in cardiology outpatient clinics. These palpitations may be derived from paroxysmal atrial fibrillation (AF) and can be easily overlooked. It is unclear whether inter-atrial conduction time (ICT) may predict the paroxysmal AF in out-patients that present with palpitations. We evaluated the ability of the ICT to predict paroxys...
متن کاملUsefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack.
BACKGROUND AND PURPOSE Although atrial fibrillation is the most frequent cause of cardioembolic stroke, this arrhythmia remains underdiagnosed, as it is often asymptomatic or intermittent and, thus, may not be detected on standard 12-lead ECG or even 24-hour ECG recording (Holter). In this study, we hypothesized that 7-day ambulatory ECG monitoring using an event-loop recording (ELR) device wou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2006