Dosimetric analysis of varying cord planning organ at risk volume in spine stereotactic body radiation therapy

نویسندگان

  • Dawn Owen
  • Charles S. Mayo
  • Limin Song
  • Kamran Ahmed
  • Nadia Laack
  • Kenneth Olivier
چکیده

BACKGROUND Spine stereotactic body radiation therapy (SBRT) is becoming widely accepted as first-line treatment of oligometastatic spine disease as well as in the postoperative setting. The reported incidence of myelopathy is very low and guidelines vary widely on the maximum tolerable dose of the spinal cord and thecal sac. METHODS AND MATERIALS Between April 2008 and December 2010, radiation parameters were exported for 46 patients treated with spine SBRT at the Mayo Clinic. Using an in-house data mining program, dose-volume histogram constraints were extracted, including dose prescription, dose fractionation, planning target volume, planning target volume coverage, maximum dose to the cord, D2cc thecal sac, and D2cc spinal cord. Diagnostic magnetic resonance imaging scans and/or computed tomography myelograms were fused with the planning set to delineate the cord and thecal sac for receiver operating characteristic analysis of cord and thecal sac subvolume doses. A high-resolution planning at-risk volume was created in 1-mm increments for cord (1-7 mm) and the thecal sac (1-2 mm) to examine dose gradients that might be correlated with toxicity. RESULTS No patients experienced myelopathy with a median follow-up of 14 months. The most common toxicities were pain and nausea. Median values of D2cc maximum dose (maximum dose received by 2 cc of the organ at risk; biologically equivalent 2-Gy dose maximum [EQD2]) for cord and thecal sac were 38.5 Gy (range, 7.5-67.9 Gy) and 67.7 Gy (range, 15.5-155.8 Gy), respectively. Median values for high-dose subvolumes for cord and thecal sac were 2 times higher than the doses for 5% predicted grade 3 cord toxicity as recommended in the current literature. Cord D0.1cc[EQD2] ≥23.8 Gy was correlated with pain flare (n = 5). Thecal sac D2cc [EQD2] ≥29.3 Gy was a significant indicator of nausea. CONCLUSION Current guidelines may overestimate the risk of myelopathy from spine SBRT. The current study's population included both radiation-naïve and retreatment cases, but no myelopathy was observed despite exceeding recommended spine limits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer.

To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Bo...

متن کامل

Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer

BACKGROUND Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach w...

متن کامل

4π noncoplanar stereotactic body radiation therapy for centrally located or larger lung tumors.

PURPOSE To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. METHODS AND MATERIALS This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were rep...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams

To investigate potential dosimetric benefits and treatment efficiency of dynamic conformal arc therapy (DCA), intensity modulated radiation therapy (IMRT), and double partial arcs Rapidarc (RA) techniques in the treatment of early-stage peripheral lung cancer using stereotactic body radiotherapy (SBRT) with flattening filter free (FFF) beams. Twenty early-stage peripheral lung cancer patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2016