Total resistance and reactance in patients with respiratory complaints with and without airways obstruction.
نویسندگان
چکیده
A comparison was made of the frequency dependence of total respiratory resistance, (Rrs), and reactance (Xrs), determined by a forced oscillation technique in 442 healthy subjects and in 126 patients with respiratory complaints, with or without slight airways obstruction. The comparison was performed by means of a discriminant analysis. The latter demonstrated that the Rrs and Xrs data, measured between 8 and 24 Hz, of patients differ from those of healthy subjects primarily by a decrease of Rrs with frequency associated with more negative Xrs (and thus with an increase in resonant frequency). This probably also applies to patients with more advanced airways obstruction. The addition of the FEV1 values to the analysis provides only a small amount of independent information. The forced oscillation technique thus appears to be a sensitive tool to separate healthy subjects (smokers and nonsmokers) from patients with respiratory complaints associated or not with a reduced FEV1.
منابع مشابه
Respiratory system impedance in patients with acute left ventricular failure: pathophysiology and clinical interest.
To investigate the relationship between alterations in lung mechanics and acute pulmonary vascular congestion, repeated measurements of the respiratory system impedance (Zrs) were performed in 11 patients with and in seven without acute left ventricular failure. Indexes of Zrs were obtained by calculating the average and slope of the resistance and reactance in low (10 to 20 Hz) and high (20 to...
متن کاملSmall airway dysfunction and flow and volume bronchodilator responsiveness in patients with chronic obstructive pulmonary disease
BACKGROUND We investigated whether a relationship between small airways dysfunction and bronchodilator responsiveness exists in patients with chronic obstructive pulmonary disease (COPD). METHODS We studied 100 (20 female; mean age: 68±10 years) patients with COPD (forced expiratory volume in 1 second [FEV1]: 55% pred ±21%; FEV1/forced vital capacity [FVC]: 53%±10%) by impulse oscillometry sy...
متن کاملبررسیارتباط بین علائمبالینی آسمو شدت کلینیکیانبا میزان تغییرات در تستهای عملکردیراههای هوایی پرگزیمال و دیستال ریه
Abstract Background & Aims: The peripheral parts of the lung are known as the main place of airflow obstruction in asthmatic patients; but the symptoms of asthma with the location of airway obstruction are still unknown. The aim of this study was to evaluate the association between asthma symptoms and severity of asthma and proximal and distal airways using function tests. Materials &...
متن کاملتعیین فراوانی عفونت ویروسی پاراآنفلوآنزا به روش ایمونوفلوئورسانس در عفونتهای حاد تنفسی
Background: Acute respiratory tract infections, both bacterial and viral, cause 4.5 million childhood deaths worldwide, most of which occur in developing countries. Parainfluenza viruses, of the paramyxoviridae family, are among the common causes of acute respiratory infections, giving rise to 30% of respiratory infections in children before school age. The four parainfluenza viruses that cause...
متن کاملOscillating Positive Expiratory Pressure on Respiratory Resistance in Chronic Obstructive Pulmonary Disease With a Small Amount of Secretion
This study aims to evaluate the acute effects of an oscillating positive expiratory pressure device (flutter) on airways resistance in patients with chronic obstructive pulmonary disease (COPD).Randomized crossover study: 15 COPD outpatients from Asthma Lab-Royal Brompton Hospital underwent spirometry, impulse oscillometry (IOS) for respiratory resistance (R) and reactance (X), and fraction exh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 83 2 شماره
صفحات -
تاریخ انتشار 1983