Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry: validation of a method for routine clinical practice.

نویسندگان

  • Marion L Cawood
  • Helen P Field
  • Clive G Ford
  • Scott Gillingwater
  • Andrew Kicman
  • David Cowan
  • Julian H Barth
چکیده

BACKGROUND Immunoassay is unsatisfactory for measuring the testosterone concentrations typically found in women. Bench-top tandem mass spectrometers are a viable alternative technology for measurements in the clinical laboratory. METHODS We used stable-isotope dilution liquid chromatography-tandem mass spectrometry (ID/LC-MS/MS) to measure testosterone in plasma and serum. The sample volume was 50 muL in duplicate; preparation and analysis were carried out in a single tube, and a batch of 192 tubes was analyzed in 17.5 h. RESULTS Intra- and interassay imprecision was <15% in the range 0.3-49 nmol/L. Recovery of testosterone added to samples at concentrations of 0.625-20 nmol/L was 96% (CV = 12%; n = 26). Six samples were serially diluted with double charcoal-stripped serum to demonstrate linearity. Correlation (r(2)) with isotope-dilution gas chromatography-mass spectrometry for 20 pools of clinical samples (range, 0.5-38.5 nmol/L) was 0.99. Correlations with our extraction RIA were 0.97 for clinical samples from men (range, 8-46.3 nmol/L) and 0.66 for samples from women (range, 0.7-3.0 nmol/L), but were 0.35 for male samples containing <3 nmol/L testosterone and 0.77 for female samples containing >8 nmol/L. Various steroids added to double charcoal-stripped serum showed no interference at the retention time of the testosterone peak. CONCLUSIONS The ID/LC-MS/MS method has improved accuracy compared with immunoassay. The low sample volume and simplicity, rapidity, and robustness of the method make it suitable for use as a high-throughput assay in routine clinical biochemistry laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid determination of serum testosterone by liquid chromatography-isotope dilution tandem mass spectrometry and a split sample comparison with three automated immunoassays.

OBJECTIVES To develop a rapid convenient-to-implement high performance liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for determination of serum testosterone concentration in routine clinical laboratories. METHODS Following extraction by organic solvents, an Agilent 1200 Series HPLC system coupled to an API 5000 mass spectrometer equipped with an atmospher...

متن کامل

Development of a candidate reference method for determination of tyrosine in serum by isotope dilution liquid chromatography-tandem mass spectrometry.

An isotope dilution liquid chromatography/tandem mass spectrometry is proposed as a reference method to determine the level of tyrosine in human serum. The advantages of this method include simple sample preparation without derivatization, the selective detection of compounds of interest in complex matrices, and the use of an isotopically labeled analogue as an internal standard. Tyrosine and i...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry.

BACKGROUND The recent interest of clinical laboratories in developing serum testosterone assays based on isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) stems from the lack of accuracy of direct immunoassays. In this study, we assessed the accuracy and state of standardization (traceability) of 4 published ID-LC-MS/MS procedures in a method comparison with an ID-ga...

متن کامل

Quantification of growth hormone in serum by isotope dilution mass spectrometry.

Interassay variation of antibody-based routine tests hampers comparability of measurement results for growth hormone (GH) between different laboratories and decision making in clinical practice. Here it is demonstrated that quantification of GH by isotope dilution mass spectrometry (IDMS) constitutes a way to obtain precise and reliable results that can be referred to in evaluation of performan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 51 8  شماره 

صفحات  -

تاریخ انتشار 2005