Fat loss during feeding of human milk.
نویسندگان
چکیده
A rise in the fat concentration of human milk within the syringe was noted towards the end of continuous infusion but not with intermittent bolus gastric feeding. The rise in the former was reduced most simply and effectively by using an eccentric nozzle syringe and tilting the pump up at an angle of between 25 degrees and 40 degrees.
منابع مشابه
Loss of breast milk nutrients during tube feeding.
Nutrient losses from banked breast milk during tube feeding were determined from laboratory models. Large fat losses occurred, continuous feeding giving rise to significantly greater losses than bolus feeding. More fat loss occurred with low flow rates and there were also significant protein losses.
متن کاملContinuous Feedings of Fortified Human Milk Lead to Nutrient Losses of Fat, Calcium and Phosphorous
Substantial losses of nutrients may occur during tube (gavage) feeding of fortified human milk. Our objective was to compare the losses of key macronutrients and minerals based on method of fortification and gavage feeding method. We used clinically available gavage feeding systems and measured pre- and post-feeding (end-point) nutrient content of calcium (Ca), phosphorus (Phos), protein, and f...
متن کاملFortifier and Cream Improve Fat Delivery in Continuous Enteral Infant Feeding of Breast Milk
Premature and high-risk infants require accurate delivery of nutrients to promote appropriate growth. Continuous enteral feeding methods may result in significant fat and micronutrient loss. This study evaluated fat loss in enteral nutrition using current strategies for providing high-risk infants fortified human milk (HM). The fat content of HM was measured by IR analyzer in a simulated feedin...
متن کاملFreezing and thawing effects on fat, protein, and lactose levels of human natural milk administered by gavage and continuous infusion.
OBJECTIVES to analyze the changes in human milk macronutrients: fat, protein, and lactose in natural human milk (raw), frozen and thawed, after administration simulation by gavage and continuous infusion. METHOD an experimental study was performed with 34 human milk samples. The infrared spectrophotometry using the infrared analysis equipment MilkoScan Minor® (Foss, Denmark) equipment was use...
متن کاملBMI and duration of breast feeding.
SIR We read with interest the study by Rutishauser and Carlini which showed that, after adjusting for the effects of confounding factors, body mass index (BMI) had a significant independent effect on the rate of cessation of breast feeding. The authors further suggest that concern regarding the lack of weight loss while breast feeding may be the basis for the association found between BMI and t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood
دوره 59 5 شماره
صفحات -
تاریخ انتشار 1984