Successful transtracheal lung ventilation using a manual respiration valve: an in vitro and in vivo study.
نویسندگان
چکیده
BACKGROUND Lung ventilation through a thin transtracheal cannula may be attempted in patients with laryngeal stenosis or "cannot intubate, cannot ventilate" situations. It may be impossible to achieve sufficient ventilation if the lungs are spontaneously emptying only through the thin transtracheal cannula, which imposes high resistance to airflow, resulting in dangerous hyperinflation. Therefore, the authors describe the use of a manual respiration valve that serves as a bidirectional pump providing not only inflation but also active deflation of the lungs in case of emergency transtracheal lung ventilation. METHODS The effectiveness of such a valve was tested in vitro using mechanical lungs in combination with two different cannula sizes and various gas flows. The valve was then tested in five pigs using a transtracheal 16-gauge cannula with three different combinations of inspiratory/expiratory times and gas flows and an occluded upper airway. RESULTS In the mechanical lungs, the valve permitted higher minute volumes compared with spontaneous lung emptying. In vivo, the arterial oxygen and carbon dioxide partial pressures increased initially and then remained stable over 1 h (arterial oxygen tension, 470.8 +/- 86.8; arterial carbon dioxide tension, 63.0 +/- 7.2 mmHg). The inspiratory pressures measured in the trachea remained below 10 cm H2O and did not substantially influence central venous and pulmonary artery pressures. Mean arterial pressure and cardiac output were unaffected by the ventilation maneuvers. CONCLUSIONS This study demonstrated in vitro and in vivo in adult pigs that satisfactory lung ventilation can be assured with transtracheal ventilation through a 16-gauge cannula for a prolonged period of time if combined with a bidirectional manual respiration valve.
منابع مشابه
An Experience with Manual Ventilation in Respiratory Paralysis Due to Indian Common Krait (Bungarus Caeruleus) Bite
Background: Bungarus caeruleus (common krait) bite during monsoon season is common in northwest India. Respiratory failure is responsible for high mortality in the victims. In this study we report our experience with manual ventilation using bag valve mask (BVM) in patients with neuroparalysis due to common krait bite. Methods:This prospective study was conducted between June 2009 and December...
متن کاملTracheal gas insufflation and related techniques to introduce gas flow into the trachea.
Over the past 50 years, a variety of techniques have been developed that have in common the insufflation of gas into the central airway to facilitate carbon dioxide (CO2) clearance. These include continuous insufflation of oxygen, transtracheal jet ventilation, high frequency jet ventilation, transtracheal oxygen administration, intratracheal pulmonary ventilation, and tracheal gas insufflation...
متن کاملAprospective randomized study comparing respiratory efficacy of percutaneous transtracheal and endotracheal, low-frequency jet ventilation during microlaryngeal surgery
Abstract Background: Transtracheal jet ventilation is an alternative ventilatory approach in airway surgery. The purpose of this study was to compare respiratory efficacy of percutaneous transtracheal with endotracheal, low frequency jet ventilation during microlaryngeal surgery. Methods: Ninety ASA class I-II patients aged between 16 and 70 years undergoing elective microlaryngeal surgery wer...
متن کاملPercutaneous Transtracheal Jet Ventilation with Various Upper Airway Obstruction
A "cannot-ventilate, cannot-intubate" situation is critical. In difficult airway management, transtracheal jet ventilation (TTJV) has been recommended as an invasive procedure, but specialized equipment is required. However, the influence of upper airway resistance (UAR) during TTJV has not been clarified. The aim of this study was to compare TTJV using a manual jet ventilator (MJV) and the oxy...
متن کاملEffects of manual hyperinflation in preterm newborns under mechanical ventilation
OBJECTIVE To assess the effects of manual hyperinflation, performed with a manual resuscitator with and without the positive end-expiratory pressure valve, on the respiratory function of preterm newborns under mechanical ventilation. METHODS Cross-sectional study of hemodynamically stable preterm newborns with gestational age of less than 32 weeks, under mechanical ventilation and dependent o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 109 2 شماره
صفحات -
تاریخ انتشار 2008