Cone directionality from laser ray tracing in normal and LASIK patients.
نویسندگان
چکیده
Laser ray tracing, a technique originally developed to measure ocular aberrations from the deviations of the local ray aberrations as a function of entry pupil, was used to assess cone directionality in 29 normal eyes (seven of which underwent LASIK surgery) and seven eyes after LASIK corneal refractive surgery for myopia. The total intensity of the retinal aerial images was computed as a function of the entry location of the illuminated beam. The measured intensity distribution was fit to a two-dimensional Gaussian function plus a constant background. The maximum of the distribution represents the pupillary location toward which the cone photoreceptors are oriented (peak of the optical Stiles-Crawford, SCE, function). We found the average SCE peak location was located 0.43 ± 0.96mm nasally and 0.60 ± 0.87mm inferiorly to the center of the pupil. In general, there was not a relation between the pupillary area of best quality and SCE peak location, either pre-operatively or post-operatively. The cone directionality shape factor was also unchanged by surgery. However, in two eyes, pre- and post-operative SCE peak location changed significantly. LASIK refractive surgery decreased the MTF in all eyes, even when the actual SCE directionality of the subject is considered. In the two eyes that showed significantly different SCE peak location, the apodized post-operative MTF with the post-operative SCE peak exceeded the simulated post-operative MTF assuming no shift in the SCE peak. However, the statistical power of these two cases is low, and the general findings are consistent with the hypothesis that differences in optical quality are not a major driving mechanism for cone orientation.
منابع مشابه
Effect of corneal aberrations on intraocular lens power calculations.
PURPOSE To use ray tracing to determine the influence of corneal aberrations on the prediction of the optimum intraocular lens (IOL) power for implantation in normal eyes and eyes with previous laser in situ keratomileusis (LASIK). SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Case series. METHODS The optimum IOL power was calculated by ray tracing using a pa...
متن کاملOcular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing.
PURPOSE To determine objectively the changes in the ocular aberrations (3rd order and above) induced by myopic LASIK refractive surgery and its impact on image quality. METHODS The ocular aberrations of 22 normal myopic eyes (preoperative refraction ranged from -13 to -2 D) were measured before (2.9 +/- 4.3 weeks) and after (7.7 +/- 3.2 weeks) LASIK refractive surgery using a laser ray tracin...
متن کاملTotal corneal power estimation: ray tracing method versus gaussian optics formula.
PURPOSE To evaluate with the use of corneal topographic data the differences between total corneal power calculated using ray tracing (TCP) and the Gaussian formula (GEP) in normal eyes, eyes that previously underwent laser in situ keratomileusis/photorefractive keratectomy (LASIK/PRK), and theoretical models. METHODS TCP and GEP using mean instantaneous curvature were calculated over the cen...
متن کاملFS200 femtosecond laser LASIK flap digital analysis parameter evaluation: comparing two different types of patient interface applanation cones
PURPOSE To evaluate the safety and efficacy of a novel LASIK flap patient interface (PI) cone with our reported digital analysis and compare for potential differences with the standard metal and glass PI in flap parameters when used with the Alcon/WaveLight FS200 femtosecond laser. PATIENTS AND METHODS Thirty-six consecutive LASIK patients (72 eyes) subjected to a bilateral femtosecond assist...
متن کاملTotal and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia.
PURPOSE To evaluate changes induced by standard laser in situ keratomileusis (LASIK) for hyperopia on total and corneal optical quality. METHODS Total and corneal aberrations were measured before and after standard hyperopic LASIK in 13 eyes (preoperative spherical equivalent refractive error +3.17 +/- 1.10 D). The Chiron Technolas 217C laser with PlanoScan was used. Total aberrations (measur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of modern optics
دوره 56 20 شماره
صفحات -
تاریخ انتشار 2009