Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw') to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm) before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03). Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12). However, the patient's implanted with a DHS did display significantly greater migration (P<0.001) than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Orthogeriatrics Current Awareness Newsletter DECEMBER 2015

Purpose: To investigate whether helical blade implant systems have advantages in terms of tip apex distance (TAD) and cut-out rate in comparison to conventional lag screws for intertrochanteric fractures in a geriatric population. Methods: Relevant articles were sourced from the MEDLINE, Embase, Ovid and Cochrane Library databases from inception through March 2015. All randomized controlled tri...

متن کامل

Dynamic hip screw blade fixation for intertrochanteric hip fractures.

PURPOSE To assess the one-year outcome of a dynamic hip screw (DHS) blade in the treatment of AO/OTA 31-A1 and 31-A2 intertrochanteric hip fractures. METHODS 35 men and 65 women aged 47 to 100 (mean, 83) years underwent fixation with a DHS blade for A1 (n=47) and A2 (n=53) intertrochanteric hip fractures after a low-energy injury. Patients were operated on within 48 hours of admission. Antero...

متن کامل

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Clinical Outcomes of Intramedullary and Extramedullary Fixation in Unstable Intertrochanteric Fractures: A Randomized Clinical Trial

Background: The best method for repairing intertrochanteric fractures is still controversial. The fixation methods includeextramedullary (EM) and intramedullary (IM). Studies that compare IM and EM fixations for unstable hip fractures arerare. In this study, our goal was to compare the efficacy of EM and IM fixation in treatment of unstable intertrochantericfractures.Met...

متن کامل

Effect of lag-screw positions on modes of fixation failure in elderly patients with unstable intertrochanteric fractures of the femur.

PURPOSE To investigate the effect of lag-screw positions in the femoral head on modes of fixation failure. METHODS 591 patients aged 65 years or older underwent sliding compression screw fixation for type A(1) (n=249) and type A(2) (n=342) intertrochanteric fractures of the femur after low-energy injuries. There were 18 cases of fixation failure; in 13 (group 1) the lag screw was placed in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017