n-Electrode three-dimensional liquid chromatography with electrochemical detection for determination of neurotransmitters.
نویسندگان
چکیده
Coulometric electrodes in series have been used with liquid chromatography with electrochemical detection to increase selectivity and resolution for the direct analysis of tissue neurotransmitters. Use of three coulometric sensors for electrochemical modification, selectivity, and peak identification has been expanded into "gate" cells of three or four coulometric electrodes that allow elimination of all electrochemically irreversible substances, and "array" cells of up to 15 coulometric electrodes for separation of co-eluting compounds by their current/voltage characteristics. On-column sensitivity of the sensor arrays is 0.4 to 4 pg. Gate cell selectivity favors electrochemically reversible compounds over irreversible ones, e.g., 3-methoxy-4-hydroxyphenylglycol vs ascorbate, by a factor of up to 10(4). Resolution across the multi-electrode array cells allows separation of co-eluting compounds with half-wave potentials differing by as little as 30 to 40 mV. Cells with three to 15 electrodes have been used to measure monoamines and metabolites in brain; monoamines directly in serum filtrate; and the state of oxidation of 5-hydroxytryptamine and 5-hydroxytryptophan in cerebrospinal fluid of patients with Alzheimer's disease.
منابع مشابه
A Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay
We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...
متن کاملSensitive Voltammetric Detection of Indomethacin Using TiO2 Nanoparticle Modified Carbon Ionic Liquid Electrode
In this work, a TiO2 nanoparticle modified carbon ionic liquid electrode (CILE) was employed as a sensitive sensor for the investigation of the electrochemical behavior of indomethacin (IND). This nanocomposite sensor has been fabricated by incorporation of TiO2 nanoparticles and the ionic liquid 1-hexylpyridinium hexafluorophosphate (HPFP). The surface of the electrode was studied by scanning ...
متن کاملElectrochemical Determination of Amitriptyline using a Nanocomposite Carbon Paste Electrode in Human Body Fluids
A carbon nanocomposite electrode has been designed by incorporation of montmorillonite nanoclayinto the carbon ionic liquid electrode for the electrochemical determination of amitriptiline . The surface ofthe proposed electrode was characterized by scanning electron microscopy. The presence of ionic liquid asa binder is believed to be responsible for the electrocatalytic activity of the propose...
متن کاملIn Vivo Determination of Tetrahydrobiop- terin and Monoamine Neurotransmitters in Rat Brain by Liquid Chromatography with a Nano Crystalline Mn-Doped Lead Dioxide Film Modified Electrode
The fabrication and application of a novel electrochemical detector (ED) with nano crystalline Mn-doped lead dioxide film chemically modified electrode (CME) for liquid chromatography (LC) were described. The Mn-doped PbO2 film was characterized by scanning tunnel microscope. The electrochemical behaviors of tetrahydrobiopterin, monoamine neurotransmitters and their metabolites at the CME were ...
متن کاملElectrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode
In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 9 شماره
صفحات -