Normal Echocardiographic Measurements in a Korean Population Study: Part II. Doppler and Tissue Doppler Imaging

نویسندگان

  • Jin-Oh Choi
  • Mi-Seung Shin
  • Mi-Jeong Kim
  • Hae Ok Jung
  • Jeong Rang Park
  • Il Suk Sohn
  • Hyungseop Kim
  • Seong-Mi Park
  • Nam Jin Yoo
  • Jung Hyun Choi
  • Hyung-Kwan Kim
  • Goo-Yeong Cho
  • Mi-Rae Lee
  • Jin-Sun Park
  • Chi Young Shim
  • Dae-Hee Kim
  • Dae-Hee Shin
  • Gil Ja Shin
  • Sung Hee Shin
  • Kye Hun Kim
  • Jae-Hyeong Park
  • Sang Yeub Lee
  • Woo-Shik Kim
  • Seung Woo Park
چکیده

BACKGROUND Hemodynamic and functional evaluation with Doppler and tissue Doppler study as a part of comprehensive echocardiography is essential but normal reference values have never been reported from Korean normal population especially according to age and sex. METHODS Using Normal echOcaRdiographic Measurements in a KoreAn popuLation study subjects, we obtained normal reference values for Doppler and tissue Doppler echocardiography including tricuspid annular velocities according to current guidelines and compared values according to gender and age groups. RESULTS Mitral early diastolic (E) and late diastolic (A) velocity as well as E/A ratio were significantly higher in women compared to those in men. Conversely, mitral peak systolic and late diastolic annular velocity in both septal and lateral mitral annulus were significantly lower in women compared to those in men. However, there were no significant differences in both septal and lateral mitral early diastolic annular (e') velocity between men and women. In both men and women, mitral E velocity and its deceleration time as well as both E/A and E/e' ratio considerably increased with age. There were no significant differences in tricuspid inflow velocities and tricuspid lateral annular velocities between men and women except e' velocity, which was significantly higher in women compared to that in men. However, changes in both tricuspid inflow and lateral annular velocities according to age were similar to those in mitral velocities. CONCLUSION Since there were significant differences in Doppler and tissue Doppler echocardiographic variables between men and women and changes according to age were even more considerable in both gender groups, normal Doppler echocardiographic values should be differentially applied based on age and sex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic Assessment of Left Ventricle Torsion by Tissue Doppler and Velocity Vector Imaging

Introduction Left ventricular (LV) twist is believed to store potential energy and plays an important role in generating diastolic suction. Recent advances in echocardiography techniques have allowed quantification of LV twist. The aim of the present study was to compare LV twist and torsion in healthy human subjects determined by velocity vector imaging (VVI) and tissue Doppler imaging (TDI) a...

متن کامل

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

I-46: Color Doppler Assessment in IUGR

Background Fetal growth restriction is the second leading cause of perinatal morbidity and mortality. The incidence of intrauterine growth restriction (IUGR) is estimated to be approximately 5 percent in the general obstetric population. Abnormal uterine artery suggest a maternal cause for the growth restriction where as normal uterine artery Doppler studies suggest that a fetal cause. Use of u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2016