Intravascular ultrasound analysis of small vessel lesions treated with the Sparrow coronary stent system: results of the CARE II trial.

نویسندگان

  • Teruyoshi Kume
  • Katsuhisa Waseda
  • Bon-Kwon Koo
  • Paul G Yock
  • Roberto Botelho
  • Stefan Verheye
  • Robert Whitbourn
  • Ian Meredith
  • Stephen Worthley
  • Koh Tian Hai
  • Yasuhiro Honda
  • Alexandre Abizaid
  • Peter J Fitzgerald
چکیده

OBJECTIVES The aim of this study was to evaluate the Sparrow sirolimus-eluting stent (Sparrow-SES) against the Sparrow bare-metal stent (Sparrow-BMS) and conventional balloon-expandable bare-metal stent (BMS: Driver/Micro-Driver stent, Medtronic Vascular, Santa Rosa, CA). BACKGROUND The Sparrow stent (Biosensors International, Singapore) consists of a guide wire-based, self-expandable, ultra-thin nitinol stent. The performance of this device with sirolimus in a fully biodegradable polymer has not been determined. METHODS A total of 74 patients were included in this intravascular ultrasound (IVUS) sub-study of the CARE II trial, which was a prospective, randomized, multicenter trial in the treatment of single de novo native coronary artery lesions in vessels ranging from 2.0 mm to 2.75 mm in diameter (Sparrow-SES: n = 31, Sparrow-BMS: n = 22, BMS: n = 21). RESULTS Stent volume index (VI) was significantly increased 8-month later in Sparrow-SES and Sparrow-BMS, but not in BMS (4.0 ± 1.0 to 4.6 ± 1.0 mm(3) /mm, p<0.0001, 4.0 ± 0.6 to 4.4 ± 0.8 mm(3) /mm, p<0.05, and 5.2 ± 1.0 to 5.1 ± 0.9 mm(3) /mm, p=0.421, respectively). % neointimal obstruction in Sparrow-SES was significantly smaller than those in Sparrow-BMS and BMS at follow-up (17.6 ± 9.4 vs. 36.2 ± 13.8 and 39.9 ± 11.1%, p<0.001). Sparrow-SES showed a mean 15% stent expansion and good suppression of neointimal proliferation, resulting in a significantly lower percentage of change in lumen VI during follow-up period (Sparrow-SES: -6.2 ± 16.2%, Sparrow-BMS: -30.4 ± 11.6%, BMS: -40.4 ± 10.0%, p<0.001). CONCLUSIONS The self-expanding Sparrow-SES demonstrated chronic stent expansion, good suppression of neointimal proliferation and resulted in a more preserved lumen in stented small vessels compared with the Sparrow-BMS and conventional balloon expandable BMS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers

Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from t...

متن کامل

Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from...

متن کامل

Volumetric analysis of in-stent intimal hyperplasia in diabetic patients treated with or without abciximab: results of the Diabetes Abciximab steNT Evaluation (DANTE) randomized trial.

BACKGROUND In diabetic patients in the Evaluation of Platelet IIb/IIIa Inhibitor for Stenting (EPISTENT) trial, abciximab reduced target vessel revascularization by approximately 50% compared with placebo. Whether this is a result of a lower restenosis rate caused by inhibition of intimal hyperplasia remains to be defined. METHODS AND RESULTS The purpose of this study was to determine whether...

متن کامل

Predictors and Long‐Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug‐Eluting Stents (ADAPT‐DES) Intravascular Ultrasound Substudy

BACKGROUND The impact of acute stent malapposition (ASM) on long-term clinical outcomes in patients undergoing percutaneous coronary intervention is still controversial. We sought to evaluate predictors and long-term clinical outcomes of ASM. METHODS AND RESULTS ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective multicenter study of 8663 patients un...

متن کامل

Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.

AIMS Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS Angiographic and intravascular ul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 83 1  شماره 

صفحات  -

تاریخ انتشار 2014