Characterization of a novel scale maille contralateral breast shield: SMART Armor

نویسندگان

  • Macinley Butson
  • Susan Carroll
  • Martin Butson
  • Robin Hill
چکیده

During breast radiotherapy treatment, the contralateral breast receives radiation doses to the skin and subcutaneous tissue caused mainly from incident electron contamination and low energy photon scatter radiation. Measurements have shown that for a typical hybrid tangential treatment, these dose levels can be up to 17% of maximum applied prescription dose if no shielding is used during the treatment process. This work examined the use of different shielding metals, aluminum, copper, and lead to reduce peripheral radiation dose to evaluate the optimal metal to form the basis of a contralateral breast radiation shield. This work also shows a simple but novel method to substantially reduce this unwanted radiation dose with the use of a copper scale maille sheet which can be easily and accurately draped over a patient's contralateral breast during treatment. The copper scale maille is flexible and can thus conform around typical breast shapes. It can also form irregular shaped edges to match those outlined by typical tangential treatment fields. As the shield is made from copper, it is nontoxic and can potentially be used directly on patients for treatment. The designed copper scale maille has shown to reduce contralateral breast skin and subcutaneous dose by up to 80% for typical radiation fields used in breast radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing a shield to reduce radiation dose during mammography: Dosimetric evaluation

Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance.  Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjac...

متن کامل

Protection of the contralateral breast during radiation therapy for breast cancer

Conformal Radiation Therapy (3DCRT) and Intensity Modulated Radiotherapy (IMRT) improve the relationship between tumor control and complications in normal tissue. However, these techniques may cause an increase of the normal tissue volume irradiated with low doses or an increase of the doses outside the beam. The aim of this work was to measure and compare the scatter dose to the contralateral ...

متن کامل

بررسی دوز پرتوی رسیده به پستان غیردرگیر، طی پرتودرمانی بیماران مبتلا به سرطان پستان ماستکتومی شده در 3 بیمارستان در تهران

    Contralateral breast dose from primary breast irradiation has been implicated in the risk of second breast malignancies. In the radiotherapy departments of Iran, based on oncologist’s and physicist’s viewpoint, a special technique and set-up may be used for treatment of chest wall in mastectomized patient. The present study compared three different breast treatment techniques and set-up use...

متن کامل

Ballistic Performance of Hybrid Armor with Ceramic Inserts and Polymeric Matrix for Different Threat Levels (TECHNICAL NOTE)

  Ceramic materials due to their high compressive strength and hardness have been one of prime candidates in armor design in particular when high level threads (impact velocity above 600m/s) are involved. The aim of this work is to investigate ballistic impact resistance potential for a target plate with novel ceramic inserts as against ceramic tiles. Two size 98% alumina (AL2O3) base ceramic i...

متن کامل

A comparison of contralateral breast dose due to breast cancer radiotherapy using two different treatment machines in a radiotherapy center

Background: The radiation dose received by contralateral breast (CLB) is one of the concerns of breast radiotherapy, because it may lead to the induction of secondary breast cancer. The aim of this study was to evaluate the CLB surface dose in the breast treatment in Yazd radiotherapy center. Materials and Methods: The surface dose of CLB was measured using TLD dosimetry in 50 cancer breast pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017