Determination of Protein Molecular Weight and Size Using the Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution with Advanced Light Scattering Detection

نویسنده

  • Sonja Schneider
چکیده

This Application Note shows the determination of protein molecular weight and size, together with linear quantifi cation using the Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution. The molecular weights and sizes of proteins, ranging from cytochrome C (11 kDa) to thyroglobulin (670 kDa) were correctly determined, independent of sample loading. Using the dual angle light scattering detector enables high sensitivity aggregation determination when compared to UV detection. Determination of Protein Molecular Weight and Size Using the Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution with Advanced Light Scattering Detection

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality analysis of virgin olive oils – Part 2 Thermal treatment analysis – determination of polymerized triglycerides with SEC/GPC using the Agilent 1260 Infi nity LC System with Refractive Index Detection

This Application Note shows the analysis of polymerized triacylglycerides in olive oil using the Agilent 1260 Infi nity LC with size exclusion chromatography/gel permeation chromatography (SEC/GPC) with refractive index detection (RID). The analysis of six virgin olive oils revealed only minor amounts of polymerized triacylglycerides (PTAGs) indicating no refi ning or other thermal treatment pr...

متن کامل

Semi - Preparative Purifi cation and Characterization of Lysozyme Modifi ed with Poly Ethylene Glycol ( PEG ) The Agilent 1260

This Application Note used hen egg white lysozyme as a model protein for purifi cation and biophysical characterization of PEGylated proteins. PEGylation to the N-terminus of lysozyme in a site-specifi c manner was achieved using PEG-propionaldehyde derivatives with a molecular weight of Mw 20,000. A semi-preparative RP-HPLC method for the purifi cation of PEGylated lysozyme was developed using...

متن کامل

Development and partial validation of a SEC method for high-resolution separation and quantifi cation of monoclonal antibodies

Size exclusion chromatography (SEC) is an important technique for the characterization of high molecular substances such as proteins or polymers. It is the standard method to determine and quantify aggregation levels for protein-based pharmaceuticals and is generally required for regulatory approval. This Application Note describes a simple and sensitive method for the quantitative analysis of ...

متن کامل

Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infi nity Analytical SFC System

This Application Note describes the development of a method for the separation of four stereoisomers, which were derived from a compound with two steric centers. The method was developed using an Agilent 1260 Infi nity Analytical Supercritical Fluid Chromatography (SFC) solution with Agilent ChemStation Method Scouting Wizard software. The developed method was used to compare the ratio of stere...

متن کامل

Determination of Sweeteners, Preservatives, and Caffeine in Various Food and Consumer Products Using the Agilent 1290 Infi nity II LC

The Agilent 1290 Infi nity II LC was used to analyze additives such as sweeteners, preservatives, and caffeine in various food products, beverages, and consumer toothpaste. The developed method facilitates accurate and sensitive determination of nine additives using a diode array detector (DAD) and an evaporative light scattering detector (ELSD) placed in series. After the DAD, a valve was inst...

متن کامل