Posterior Cerebral Infarction following Loss of Guide Wire
نویسندگان
چکیده
Stroke after internal jugular venous cannulation typically leads to acute carotid or vertebral arteries injury and cerebral ischemia. We report the first case of delayed posterior cerebral infarction following loss of guide wire after left internal jugular venous cannulation in a 46-year-old woman with a history of inflammatory bowel disease. Our observation highlights that loss of an intravascular guide wire can be a cause of ischemic stroke in patients undergoing central venous catheterization.
منابع مشابه
Rupture of a cerebral aneurysm during embolization for a cerebral arteriovenous malformation.
An aneurysm ruptured during superselective catheterization into the posterior cerebral artery for a left temporal arteriovenous malformation. The rupture may have been caused by stretching and displacement of the basilar and posterior cerebral arteries while the microcatheter with guide wire was advanced.
متن کاملNovel rat middle cerebral artery occlusion model: Trans-femoral artery approach combined with preservation of the external carotid artery.
We developed a novel trans-femoral artery approach to the rat middle cerebral artery occlusion model (TF-MCAO) without sacrificing the external carotid artery (ECA) with/without the pterygopalatine artery, which is important for chewing food. To make the TF-MCAO we first dissect the left common carotid artery (CCA), ECA, and internal carotid artery (ICA). Transient occlusion clips are applied t...
متن کاملSimultaneous Loss of Bilateral Voluntary Eyelid Opening and Sustained Winking Response Following Bilateral Posterior Cerebral Artery Infarction
Spontaneous opening and closing of both eyes usually occurs in the normal awake state, unless a deliberate and voluntary attempt is made to open only one eye. We present a rare case of a male patient who was unable to open both eyes simultaneously after bilateral posterior cerebral artery infarction. He was able to close both eyes voluntarily. However, he was unable to keep both eyes open simul...
متن کاملMultivariate Analysis of Risk Factors of Cerebral Infarction in 439 Patients Undergoing Thoracic Endovascular Aneurysm Repair
The aim of the study is to identify the potential risk factors of cerebral infarction associated with thoracic endovascular aneurysm repair (TEVAR). TEVAR was developed as a less invasive surgical alternative to conventional open repair for thoracic aortic aneurysm treatment. However, outcomes following TEVAR of aortic and distal arch aneurysms remain suboptimal. Cerebral infarction is a major ...
متن کاملDetection of embolic particles with the Doppler guide wire during coronary intervention in patients with acute myocardial infarction: efficacy of distal protection device.
OBJECTIVES We investigated whether embolic particles could be detected as high-intensity transient signals (HITS) with a Doppler guide wire during percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) We also assessed whether these signals could be reduced using a distal protection (DP) device. BACKGROUND Embolization of thrombi and plaque components to t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013