Prospective Durability Testing of a Vascular Access Phantom

نویسندگان

  • Joel M. Schofer
  • Jason T. Nomura
  • Michael J. Bauman
  • Paul R. Sierzenski
چکیده

INTRODUCTION We assessed the acoustic transmission, image quality, and vessel integrity of the Blue Phantom™ 2 Vessel Original Ultrasound Training Model with repeated use. METHODS The study consisted of two phases. During the first phase, a portion of the Blue Phantom™ rubber matrix (without a simulated vessel) was placed over a two-tiered echogenic structure and was repeatedly punctured with a hollow bore 18-gauge needle in a 1 cm(2) area. During the second phase, a portion of the matrix with a simulated vessel was repeatedly punctured with another hollow bore 18-gauge needle. During both phases we obtained an ultrasound image using a high-frequency linear probe after every 100 needle punctures to assess the effect of repeated needle punctures on image quality, acoustic transmission, and simulated vessel integrity. RESULTS Testing on the rubber matrix alone (first phase) without a vessel demonstrated a gradual decrease in image quality and visualization of the proximal and distal portions of the target structure, but they remained visible after 1,000 needle punctures. The second phase demonstrated excellent acoustic transmission and image quality on both transverse and longitudinal images of the rubber matrix and simulated vessel after 1,000 needle punctures. The anterior and posterior vessel walls and needle tip were well visualized without any signs of vessel leakage on still images or with compression and power Doppler. CONCLUSION The Blue Phantom™ 2 Vessel Original Ultrasound Training Model demonstrated excellent durability after 1,000 needle punctures in a 1- cm(2) area. Based on the length of simulated vessel in each model, it should support over 25,000 simulated attempts at vascular access.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی میزان کارایی و عوارض گرافت صناعی عروقی پلی تترا فلورو اتیلن در بیماران همودیالیزی

Background: Dialysis access procedures and complications are important causes of morbidity and hospitalization for chronic hemodialysis patients. Ideally, any patient undergoing hemodialysis should receive an autogenous fistula that can be accessed throughout the patient's life. In patients with primarily unsuitable or secondarily surgically-exhausted veins, a prosthetic graft can be performed....

متن کامل

Stent graft versus balloon angioplasty for failing dialysis access grafts: a long-awaited advance in the treatment of permanent hemodialysis access.

Arteriovenous grafts (AVGs) for hemodialysis have a high failure rate, often due to the development of stenosis at the graft-to-vein anastomosis. Angioplasty (PTA) has been used for over two decades to treat AVG stenosis, with good technical success but limited AVG patency. Results of a prospective multi-center randomized trial, comparing stent graft to PTA in AVGs, has demonstrated superior ac...

متن کامل

Bias in Amputation Research; Impact of Subjects Missed from a Prospective Study

For research findings to be generalized, a sample must be representative of the actual population of interest. Lower limb amputation is most frequently performed in older patients with vascular disease, a population that is often under-represented in research. The aim of this study was to explore the impact of selection bias by comparing characteristics from a sample included in a prospective s...

متن کامل

Feasibility of using Medical Imaging Interaction Toolkit in volumetric studies to accurate diagnosing of vascular emboli by Extended NURBS-based Cardiac-Torso phantom

Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated....

متن کامل

Effect of combination of alcohol and Betadine on the severity of inflammation in the vascular access site in hemodialysis patients

Background: Inflammation in the vascular access site results in infection, which is the second leading cause of death in hemodialysis patients. However, there is no specific protocol available for sterilization before vascular access in such patients. Aim: to determine the effect of the combination of alcohol and Betadine on the severity of inflammation in the vascular access site in hemodialys...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010