Influence of drugs on clinical chemical data for serum glucose, investigated with the automated glucose oxidase-perid method.
نویسندگان
چکیده
Fifty drugs, applied in the therapy of internal diseases, were investigated for their effect on the clinical chemical determination of serum glucose by the automated GOD-Perid method. The results showed a statistically significant depression of the reported glucose value, by 7 drugs containing the pyrazolone group and its derivatives (Baralgin, Butazolidine, Analgin, Novalgetol, Analgocain, Irgapyrin, Aminopyrin) P less than 0.001; P less than 0.01. The influence depends on the quantity of drug and on the time interval between loading and glucose analysis.
منابع مشابه
Mechanism of interference by uric acid in the glucose oxidase-peroxidase method for serum glucose.
A number of chromogens have been proposed in the past. In the glucose oxidase “GOD-Perid”1 method, the subject of study in this paper, ABTS is used as the chromogen (6). Unfortunately, the glucose oxmdase methods are not free of interference from other substances, uric acid being one. Here, I examine each reaction step of the GOD-Perid method, discuss possible mechanisms of interference by uric...
متن کاملAn automated, saccharogenic method for determining serum amylase activity.
An automated adaptation of the Somogyl saccharogenic determination of serum amylase is described in which conventional AutoAnalyzer modules are used. Adequate sensitivity with short incubation is achieved by incorporating glucose oxidase and catalase in the substrate to destroy serum glucose during incubation. Maltose and other dialyzable oligosaccharides are measured with the alkaline copper-n...
متن کاملA Simple Image Analysis Method for Determination of Glucose by using Glucose Oxidase CdTe/TGA Quantum Dots
Glucose, as the major energy source in cellular metabolism, plays an important role in the natural growth of cells. Herein, a simple, rapid and low-cost method for the glucose determination by utilizing glucose oxidase and CdTe/thioglycolic acid (TGA) quantum dots (QDs) on a thin layer chromatography (TLC) plate has been described. The detection was based on the combination of the glucose enzym...
متن کاملKinetic enzymatic method for automated determination of glucose in blood and serum.
Studies are reported on the reaction kinetics of the glucose assay according to Trinder which involves the specific oxidation of glucose by glucose oxidase and the determination of the hydrogen peroxide released by means of phenol and 4-aminophenazone in the presence of peroxidase. The results have been used to develop a general kinetic fixed-time method for the analysis of glucose in whole blo...
متن کاملThe obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4
The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie
دوره 15 10 شماره