Rapid determination of gold in geological samples using flow injection solid-phase chemiluminescence.

نویسندگان

  • Jun-Feng Li
  • Li-Fei Bai
  • Ying-Hua Wang
  • Hong-Yan Wang
چکیده

The solid-phase chemiluminescence analysis of gold on the surface of an anion-exchange resin was studied. A method for the fast determination of gold using flow injection was established. The anion-exchange resin was used as an adsorbent of gold ion in the form of AuCl4-. The cation-exchange resin was used for the on-line separation of cations in the matrix. To obtain the best results, the preconcentration and separation conditions, chemiluminescence conditions, interfering ions and their elimination conditions were optimized. The linear range of the calibration curve of AuCl4- is from 0 microg ml(-1) to 5.00 microg ml(-1). The detection limit of AuCl4- is 0.012 microg ml(-1). The method has been used for the determination of gold in geological samples (standard ores). The results are in agreement with certified value of gold standard samples with relative standard deviation from 2.22% to 8.97%. Through the use of flow injection, the preconcentration and separation can be performed automatically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecularly imprinted solid-phase extraction and flow-injection chemiluminescence for trace analysis of 2,4-dichlorophenol in water samples.

Highly sensitive flow-injection chemiluminescence (CL) combined with molecularly imprinted solid-phase extraction (MISPE) has been used for determination of 2,4-dichlorophenol (2,4-DCP) in water samples. The molecularly imprinted polymer (MIP) for 2,4-DCP was prepared by non-covalent molecular imprinting methods, using 4-vinylpyridine (4-VP) and ethylene glycol dimethacrylate (EGDMA) as the mon...

متن کامل

Flow injection photoinduced chemiluminescence determination of imazalil in water samples.

In this work, a fast, simple and economic method is proposed for the determination of imazalil in water samples by flow injection photoinduced chemiluminescence. In this method, imazalil degrades in basic media through the use of a photoreactor, and the resulting photofragments react with ferricyanide and generate the direct chemiluminescence signal. To the authors' knowledge, this is the first...

متن کامل

Selective and Sensitive Chemiluminescence Determination of Mcpb: Flow Injectin and Liquid

Two new chemiluminescence methods are described for the determination of herbicide MCPB. Firstly, a flow injection chemiluminescence (FI-CL) method is proposed. In this method, MCPB is photodegraded with a UV lamp and the photoproducts formed provide a great chemiluminescence signal when they react with ferricyanide in basic medium. Secondly, an HPLC chemiluminescence (HPLC-CL) method is propos...

متن کامل

FI-photoinduced chemiluminescence method for diuron determination in water samples.

A new method for the determination of the herbicide diuron, using a flow injection manifold and photoinduced chemiluminescence detection, is presented. The pesticide, in basic medium, was irradiated on-line with UV light (254 nm) for 53 s. A short discussion about the possible irradiation products is included. The chemiluminescent response of the photoproducts was induced by oxidation with pota...

متن کامل

A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2006