Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure
نویسندگان
چکیده
INTRODUCTION Elevated intracranial pressure (ICP) is a major and potentially lethal disorder in patients admitted to the emergency department (ED). Several methods are being used to investigate for elevated ICP. Here we assessed and compared the diagnostic accuracy of two existing tools of ophthalmoscopy and optic nerve ultrasonography in detection of elevated ICP. METHODS 131 participants with probable elevation of ICP referred to the emergency department of Al-Zahra Hospital, Isfahan, Iran, from 2012 to 2014, were enrolled. Brain computed tomography (CT) scan, ultrasonography of optic nerve sheath, and ophthalmoscopy were performed for them. The optic nerves sheath with diameter more than 5 millimeters was considered as elevated ICP. Widening of optic nerve, ocular venous engorgement, blurring, hemorrhage over optic disk, elevation of optic disk, and retinal venous tortuosity were recorded as evidences of ICP rising in ophthalmoscopy. Diagnostic accuracy of the two tools in prediction of ICP rising were compared with the results of brain CT scan as a gold standard. RESULTS The mean age of participants was 46.29 ± 10 years (77% male). The number of diagnosed elevated ICPs with ophthalmoscopy and ultrasound were 98 (74.8%) and 102 (77.9%) cases, respectively. The calculated sensitivity and specificity of ophthalmoscopy and ultrasonography in detection of ICP rising were 100.0% (95% CI: 88.6-100.0) and 35.4% (95% CI: 26.0-46.2), 100.0% (95% CI: 84.0-100.0) and 31.9% (95% CI: 23.0-41.7), respectively. CONCLUSION The present study revealed that bedside ultrasonography of optic nerve sheath and ophthalmoscopy have enough accuracy for the screening of patients with probable elevation of ICP. Of course, it should be considered that despite the high sensitivity of both tools, their specificity is low.
منابع مشابه
Elevated Intracranial Pressure Diagnosis with Emergency Department Bedside Ocular Ultrasound
Bedside sonographic measurement of optic nerve sheath diameter can aid in the diagnosis of elevated intracranial pressure in the emergency department. This case report describes a 21-year-old female presenting with 4 months of mild headache and 2 weeks of recurrent, transient binocular vision loss. Though limited by patient discomfort, fundoscopic examination suggested the presence of blurred o...
متن کاملSonographic Optic Nerve Sheath Diameter as a Screening Tool for Detection of Elevated Intracranial Pressure
INTRODUCTION Timely diagnosis and treatment of post-traumatic elevated intracranial pressure (EICP) could be reduced morbidity and mortality, and improved patients' outcome. This study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (ONSD) in detection of EICP. METHODS Sonographic ONSD of patients with head trauma or cerebrovascular accident suspicious...
متن کاملEffect of scuba-diving on optic nerve and sheath diameters
Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated. Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...
متن کاملOptic Nerve Sonography in the Diagnostic Evaluation of Pseudopapilledema and Raised Intracranial Pressure: A Cross-Sectional Study
Introduction. Differentiating pseudopapilledema from papilledema which is optic disk edema and a result of increased ICP (intracranial pressure) is important and can be done with noninvasive methods like orbital ultrasound examination. Method. This was a cross-sectional study in which patients with optic nerve head swelling were referred for LP exam after optic nerve head swelling diagnosis con...
متن کاملIndividual patient data systematic review and meta-analysis of optic nerve sheath diameter ultrasonography for detecting raised intracranial pressure: protocol of the ONSD research group
BACKGROUND The purpose of the optic nerve sheath diameter (ONSD) research group project is to establish an individual patient-level database from high quality studies of ONSD ultrasonography for the detection of raised intracranial pressure (ICP), and to perform a systematic review and an individual patient data meta-analysis (IPDMA), which will provide a cutoff value to help physicians making ...
متن کامل