Differences between stereopsis with isoluminant and isochromatic stimuli.
نویسندگان
چکیده
Contrast thresholds for stereoscopic depth identification (crossed or uncrossed) were measured as a function of disparity by use of isoluminant (red-green) and isochromatic (yellow-black) 0.5 cycles/deg Gabor patches. For the purposes of comparison, stimulus contrasts were scaled by their respective detection thresholds. The Gabor patches could be either vertically or horizontally oriented. It was found that the disparity dependence of the depth-identification contrast thresholds was similar for both chromatic and luminance patterns if the stimuli were vertically oriented, with the overall level of performance worse for the chromatic patterns by a factor of approximately 2 (6 dB). With horizontal patterns this difference was much larger, by a factor of approximately 7 (17 dB). These results suggest first that stereopsis in the absence of luminance cues is supported by a less-contrast-sensitive linear mechanism than that which supports stereopsis in the presence of luminance cues and second that the corresponding nonlinear chromatic stereo mechanism is either nonexistent or very weak. The implications of these data for previous studies of stereopsis at isoluminance is discussed.
منابع مشابه
On the apparent collapse of stereopsis in random-dot-stereograms at isoluminance
We have investigated the apparent collapse of stereopsis obtained with random-dot-stereograms at isoluminance. Contrast thresholds for both depth and form discrimination of targets in random-dot- and figural stereograms were measured at a number of disparitics, using both isoluminant and isochromatic stimuli. All contrast thresholds for stereoscopic tasks were normalised to contrast thresholds ...
متن کاملContrast thresholds for stereoscopic depth identification with isoluminant and isochromatic stimuli.
Contrast thresholds for stereoscopic depth identification (crossed or uncrossed) were measured as a function of disparity using isoluminant (red-green) and isochromatic (yellow-black) 0.5 c/deg Gabor patches. For the purposes of comparison stimulus contrasts were scaled by their respective detection thresholds. The detection thresholds employed were computed from the monocular detection thresho...
متن کاملInteractions between chromatic- and luminance-contrast-sensitive stereopsis mechanisms
It is well known that chromatic information can assist in solving the stereo correspondence problem. It has also been suggested that there are two independent first-order stereopsis mechanisms, one sensitive to chromatic contrast and the other sensitive to luminance contrast (Vision Research 37 (1997) 1271). Could the effect of chromatic information on stereo correspondence be subserved by inte...
متن کاملEfficiency in detection of isoluminant and isochromatic interference fringes.
We examined the limitations imposed by neural factors on spatial contrast sensitivity for both isochromatic and isoluminant gratings. We used two strategies to isolate these neural factors. First, we eliminated the effect of blurring by the dioptrics of the eye by using interference fringes. Second, we corrected our data for additional sensitivity losses up to and including the site of photon a...
متن کاملA linear chromatic mechanism drives the pupillary response.
Previous studies have shown that a chromatic mechanism can drive pupil responses. The aim of this research was to clarify whether a linear or nonlinear chromatic mechanism drives pupillary responses by using test stimuli of various colours that are defined in cone contrast space. The pupil and accommodation responses evoked by these test stimuli were continuously and simultaneously objectively ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 12 10 شماره
صفحات -
تاریخ انتشار 1995