Robotic knee laxity testing: reliability and normative data.
نویسندگان
چکیده
PURPOSE To evaluate the reliability of the GeNouRoB knee arthrometer and present normative values of knee anterior laxity using this device on young females. METHODS Anterior laxity in both knees was tested in two groups of young, uninjured females using the hamstrings electromyography biofeedback feature of the device. There were 13 participants in the group tested for reliability and 23 for the normative study. Laxity (mm of movement of the proximal tibia in the anterior direction relative to the femur) was calculated at test forces of 134 N and 250 N with values presented for the unstandardised and standardised (relative to stabilisation force) conditions. RESULTS The relative reliability (95% limits of agreement) of the device for laxity at a test force of 134 N was 2 to 3mm. Left knee anterior laxity was almost 1mm greater than the right. CONCLUSIONS The relative reliability of the GeNouRoB arthrometer is comparable to the KT device. In agreement with previous work on the nonrobotic KT arthrometer, the knee anterior laxity values found with the GeNouRoB are greater in the left as compared to the right knee.
منابع مشابه
Reproducibility of instrumented knee joint laxity measurement in healthy subjects.
OBJECTIVE To determine the reproducibility of frontal plane knee joint laxity measurement through the assessment of intra- and inter-rater reliability coefficients and intra- and inter-rater agreement coefficients. METHODS Two raters independently assessed the laxity of the knee joint in the frontal plane by three repeated measurements. Fourteen days later the assessment was repeated. Complet...
متن کاملRotational knee laxity: Reliability of a simple measurement device in vivo
BACKGROUND Double bundle ACL reconstruction has been demonstrated to decrease rotational knee laxity. However, there is no simple, commercially-available device to measure knee rotation. The investigators developed a simple, non-invasive device to measure knee rotation. In conjunction with a rigid boot to rotate the tibia and a force/moment sensor to allow precise determination of torque about ...
متن کاملKnee Laxity or Loss of Knee Range of Motion after PCL Reconstruction: A Systematic Review and Meta-Analysis
Background. PCL reconstruction is a successful method for enhancing the patientchr('39')s quality of life but posterior knee laxity and knee stiffness have still occurred surgery. There is no study to evaluate knee laxity or loss of knee range of motion after surgery. Objectives. To assess the outcomes after PCL reconstruction, we: 1) evaluated the range of motion of the knee, 2) evaluated pos...
متن کاملTest-retest reliability of repeated knee laxity measurements in the acute phase following a knee trauma using a Rolimeter
The purpose was to examine the test-retest reliability of the Rolimeter measurement procedure in the acute time phase, following a substantial knee trauma. In total, 15 participants with acute knee trauma were examined by one single observer at three different time-points with the Rolimeter using a maximum force. The selected time-points were: baseline (0-7 days after the trauma), midpoint (3-4...
متن کاملRelationship between knee joint laxity and knee joint mechanics during the menstrual cycle.
BACKGROUND An increase in knee laxity during the menstrual cycle may increase the risk of anterior cruciate ligament injury. OBJECTIVE To investigate whether changing knee laxity during the menstrual cycle correlates with changing knee joint loads in a cutting manoeuvre. DESIGN Cross-sectional study. SETTING Laboratory testing. PARTICIPANTS 25 healthy women, with a normal menstrual cycl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Knee
دوره 20 4 شماره
صفحات -
تاریخ انتشار 2013