Comparison of Three-Dimensional Isotropic and Two-Dimensional Conventional Indirect MR Arthrography for the Diagnosis of Rotator Cuff Tears

نویسندگان

  • Ji Hyun Lee
  • Young Cheol Yoon
  • Sukkyung Jee
  • Jong Won Kwon
  • Jang Gyu Cha
  • Jae Chul Yoo
چکیده

OBJECTIVE To compare the accuracy between a three-dimensional (3D) indirect isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) arthrography and a conventional two-dimensional (2D) T1-weighted sequences of indirect MR arthrography for diagnosing rotator cuff tears. MATERIALS AND METHODS The study was approved by our Institutional Review Board. In total, 205 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery for 206 shoulders were included in this study. Both conventional 2D T1-weighted FSE sequences and 3D isotropic T1-weighted FSE sequence were performed in all patients. Two radiologists evaluated the images for the presence of full- or partial-thickness tears in the supraspinatus-infraspinatus (SSP-ISP) tendons and tears in the subscapularis (SSC) tendons. Using the arthroscopic findings as the reference standard, the diagnostic performances of both methods were analyzed by the area under the receiver operating characteristic curve (AUC). RESULTS Arthroscopy confirmed 165 SSP-ISP tendon tears and 103 SSC tendon tears. For diagnosing SSP-ISP tendon tears, the AUC values were 0.964 and 0.989 for the 2D sequences and 3D T1-weighted FSE sequence, respectively, in reader I and 0.947 and 0.963, respectively, in reader II. The AUC values for diagnosing SSC tendon tears were 0.921 and 0.925, respectively, for reader I and 0.856 and 0.860, respectively, for reader II. There was no significant difference between the AUC values of the 2D and 3D sequences in either reader for either type of tear. CONCLUSION 3D indirect isotropic MR arthrography with FSE sequence and the conventional 2D arthrography are not significantly different in terms of accuracy for diagnosing rotator cuff tears.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect MRA has More Diagnostic Value than Conventional MRI in Partial and Subscapularis Tears of Rotator Cuff

Background and purpose: Determining the severity and site of rotator cuff tear (RCT) is very important for choosing a treatment method. In this study, the diagnostic value of indirect magnetic resonance arthrography (I-MRA) and magnetic resonance imaging (MRI) were compared. Materials and methods: This cross-sectional study was performed in 36 patients attending an orthopedic clinic in 2020. P...

متن کامل

Accuracy of MRI, MR arthrography, and ultrasound in the diagnosis of rotator cuff tears: a meta-analysis.

OBJECTIVE The purpose of this study was to compare the diagnostic accuracy of MRI, MR arthrography, and ultrasound for the diagnosis of rotator cuff tears through a meta-analysis of the studies in the literature. MATERIALS AND METHODS Articles reporting the sensitivities and specificities of MRI, MR arthrography, or ultrasound for the diagnosis of rotator cuff tears were identified. Surgical ...

متن کامل

Comparisons of the Various Partial-Thickness Rotator Cuff Tears on MR Arthrography and Arthroscopic Correlation

OBJECTIVE To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings. MATERIALS AND METHODS The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a con...

متن کامل

Diagnosis of tears in rotator-cuff-injuries.

Pathology of the rotator cuff is the cause of most common problems at the shoulder joint. Acute injuries are not as frequent as chronic cuff disease, but often they aggravate inflammatory or degenerative tendon alterations, even if they are of minor severity. Traumatic rotator cuff tears predominantly affect the supraspinatus tendon or the rotator interval. The subscapularis tendon is involved ...

متن کامل

MR imaging for traumatic tears of the rotator cuff: high prevalence of greater tuberosity fractures and subscapularis tendon tears.

OBJECTIVE The purpose of this study was to determine whether occult bony injuries or other characteristic MR abnormalities are frequent in patients suspected of having traumatic tears of the rotator cuff. SUBJECTS AND METHODS MR arthrography of the shoulder was performed in 24 consecutive patients with suspected traumatic tears of the rotator cuff. MR findings were analyzed with regard to abn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014