Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization: a literature review.

نویسندگان

  • Gero S M Kinzinger
  • Mert Eren
  • Peter R Diedrich
چکیده

Since the end of the 1970s, various appliances with intramaxillary anchorage for distalization of the upper molars have been described as an alternative to headgear. The major advantages of these innovative appliances are that they act permanently and are independent of patient compliance. The purpose of this study was to compare the efficiency, both quantitatively and qualitatively, of various appliance types with intramaxillary anchorage for non-compliance molar distalization. Eighty-five papers were reviewed, and 22 were identified as being suitable for inclusion. The selection was based on compliance with the following criteria: treatment group with at least 10 non-syndromal patients, conventional intraoral anchorage design using a palatal button and anchorage teeth, consistent cephalometric measurements in clinical-epidemiological studies, exact data on the course of treatment, and statistical presentation of the measured outcomes and their standard deviations. The results show that non-compliance molar distalization is possible with numerous different appliances. While molar distalization with standard pendulum appliances exhibited the largest values for dental-linear distalization, it also resulted in concurrent, substantial therapeutically undesirable distal tipping. However, specific modifications to the pendulum appliance allow achievement of almost bodily molar distalization. Different outcomes are quoted in the studies for the efficiency of loaded spring systems for distal molar movement, but it seems that the first class appliance and the palatal distal jet are more efficient than the vestibular Jones Jig. The studies identify anchorage loss as being found in the area of the incisors rather than the area of the first premolars. There was a trend for more substantial reciprocal side-effects to occur when only two teeth were included in the anchorage unit. Vertical components acting on the molars, premolars, and incisors, such as intrusion and extrusion, tended to be of secondary importance and, therefore, may be disregarded.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molar Distalization By Miniplates- A Review

Treatment of Class II malocclusions, without extractions, frequently requires distalization of maxillary molars into a Class I relationship by means of extra-oral or intraoral forces. Several methods and devices can be used to distalize maxillary molars and to correct Class II malocclusions. The most conventional method for distalizing the maxillary molars involves use of cervical headgear but ...

متن کامل

Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review.

OBJECTIVE To use published data to evaluate quantitatively the dental effects of noncompliance intramaxillary appliances in individuals with Class II malocclusion. MATERIALS AND METHODS A literature search was carried out identifing 13 prospective or retrospective clinical studies matching inclusion criteria. Only appliances with conventional anchorage designs were considered for the review. ...

متن کامل

Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization.

INTRODUCTION Conventional anchorage appliances rely exclusively on intraoral anchorage for noncompliance molar distalization. The partial coverage of the palate, in particular, often results in compromised oral hygiene. An innovative alternative combines a skeletonized distal jet appliance with 2 paramedian miniscrews for additional anchorage. The objectives of this study were to investigate th...

متن کامل

Fabrication and Evaluation of a Noncompliant Molar Distalizing Appliance: Bonded Molar Distalizer

OBJECTIVE Attempts to treat class II malocclusions without extraction in non-compliant patients have led to utilization of intraoral molar distalizing appliances. The purpose of this study was to investigate dental and skeletal effects of Bonded Molar Distalizer (BMD) which is a simple molar distalizing appliance. MATERIALS AND METHODS Sixteen patients (12 girls, four boys) with bilateral hal...

متن کامل

Distal Driving Of Molars – A Review

Distalization of maxillary molars with intraoral appliance is a non-extraction treatment approach for correction of Class II malocclusion that has been described as an alternative to headgear. The aim of this review article is to discuss about the various criteria that should be considered while deciding to distalize molars and a comprehensive review of commonly used intraoral molar distalizati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 30 6  شماره 

صفحات  -

تاریخ انتشار 2008