Correction of errors in scale values for magnetic elements for Helsinki
نویسنده
چکیده
Using several lines of evidence we show that the scale values of the geomagnetic variometers operating in Helsinki in the 19th century were not constant throughout the years of operation 1844–1897. Specifically, the adopted scale value of the horizontal force variometer appears to be too low by ∼ 30 % during the years 1866–1874.5 and the adopted scale value of the declination variometer appears to be too low by a factor of ∼ 2 during the interval 1885.8–1887.5. Reconstructing the heliospheric magnetic field strength from geomagnetic data has reached a stage where a reliable reconstruction is possible using even just a single geomagnetic data set of hourly or daily values. Before such reconstructions can be accepted as reliable, the underlying data must be calibrated correctly. It is thus mandatory that the Helsinki data be corrected. Such correction has been satisfactorily carried out and the HMF strength is now well constrained back to 1845.
منابع مشابه
An approach to fault detection and correction in design of systems using of Turbo codes
We present an approach to design of fault tolerant computing systems. In this paper, a technique is employed that enable the combination of several codes, in order to obtain flexibility in the design of error correcting codes. Code combining techniques are very effective, which one of these codes are turbo codes. The Algorithm-based fault tolerance techniques that to detect errors rely on the c...
متن کاملروشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملGrammatical Error Correction of English as Foreign Language Learners
This study aimed to discover the insight of error correction by implementing two correction systems on three Iranian university students. The three students were invited to write four in-class essays throughout the semester, in which their verb errors and individual-selected errors were corrected using the Code Correction System and the Individual Correction System. At the end of the study, the...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملMagnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...
متن کامل