Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study.

نویسندگان

  • S P Knops
  • N W L Schep
  • C W Spoor
  • M P J M van Riel
  • W R Spanjersberg
  • G J Kleinrensink
  • E M M van Lieshout
  • P Patka
  • I B Schipper
چکیده

BACKGROUND Pelvic circumferential compression devices are designed to stabilize the pelvic ring and reduce the volume of the pelvis following trauma. It is uncertain whether pelvic circumferential compression devices can be safely applied for all types of pelvic fractures because the effects of the devices on the reduction of fracture fragments are unknown. The aim of this study was to compare the effects of circumferential compression devices on the dynamic realignment and final reduction of the pelvic fractures as a measure of the quality of reduction. METHODS Three circumferential compression devices were evaluated: the Pelvic Binder, the SAM Sling, and the T-POD. In sixteen cadavers, four fracture types were generated according to the Tile classification system. Infrared retroreflective markers were fixed in the different fracture fragments of each pelvis. The circumferential compression device was applied sequentially in a randomized order with gradually increasing forces applied. Fracture fragment movement was studied with use of a three-dimensional infrared video system. Dynamic realignment and final reduction of the fracture fragments during closure of the circumferential compression devices were determined. A factorial repeated-measures analysis of variance with pairwise post hoc comparisons was performed to analyze the differences in pulling force between the circumferential compression devices. RESULTS In the partially stable and unstable (Tile type-B and C) pelvic fractures, all circumferential compression devices accomplished closure of the pelvic ring and consequently reduced the pelvic volume. No adverse fracture displacement (>5 mm) was observed in these fracture types. The required pulling force to attain complete reduction at the symphysis pubis varied substantially among the three different circumferential compression devices, with a mean (and standard error of the mean) of 43 ± 7 N for the T-POD, 60 ± 9 N for the Pelvic Binder, and 112 ± 10 N for the SAM Sling. CONCLUSIONS The Pelvic Binder, SAM Sling, and T-POD provided sufficient reduction in partially stable and unstable (Tile type-B1 and C) pelvic fractures. No undesirable overreduction was noted. The pulling force that was needed to attain complete reduction of the fracture parts varied significantly among the three devices, with the T-POD requiring the lowest pulling force for fracture reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness and complications of pelvic circumferential compression devices in patients with unstable pelvic fractures: a systematic review of literature.

BACKGROUND Pelvic fractures can cause massive haemorrhage. Early stabilisation and compression of unstable fractures is thought to limit blood loss. Reposition of fracture parts and reduction of pelvic volume may provide haemorrhage control. Several non-invasive techniques for early stabilisation have been proposed, like the specifically designed pelvic circumferential compression devices (PCCD...

متن کامل

Noninvasive reduction of open-book pelvic fractures by circumferential compression.

OBJECTIVES To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN Biomechanical investigation on human cadaveric specimens. SETTING Biomechanics laboratory. INTERVENTION Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created ...

متن کامل

Measurements of the Exerted Pressure by Pelvic Circumferential Compression Devices

BACKGROUND Data on the efficacy and safety of non-invasive Pelvic Circumferential Compression Devices (PCCDs) is limited. Tissue damage may occur if a continuous pressure on the skin exceeding 9.3 kPa is sustained for more than two or three hours. The aim of this study was to gain insight into the pressure build-up at the interface, by measuring the PCCD-induced pressure when applying pulling f...

متن کامل

Emergent stabilization of pelvic ring injuries by controlled circumferential compression: a clinical trial.

BACKGROUND Pelvic ring injuries are associated with a high incidence of mortality mainly due to retroperitoneal hemorrhage. Early stabilization is an integral part of hemorrhage control. Temporary stabilization can be provided by a pelvic sheet, sling, or an inflatable garment. However, these devices lack control of the applied circumferential compression. We evaluated a pelvic circumferential ...

متن کامل

Pelvic circumferential compression in the presence of soft-tissue injuries: a case report.

Unstable pelvic ring disruptions are frequently associated with hemodynamic instability. Although the source of hemorrhage can be from multiple sites, the severity and type of pelvic disruption strongly correlates with retroperitoneal blood loss. Pelvic stabilization in the early posttraumatic phase is reported to provide an effective means of controlling this retroperitoneal hemorrhage. Pelvic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 93 3  شماره 

صفحات  -

تاریخ انتشار 2011