The CodacsTM Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency

نویسندگان

  • Martin Grossöhmichen
  • Rolf Salcher
  • Hans-Heinrich Kreipe
  • Thomas Lenarz
  • Hannes Maier
چکیده

This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RWwas adjusted to ~ 5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5–141.8 eq. dB SPL; Omega/Aerial: 123.6–143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6–131.6 eq. dB SPL) and RW stimulation (108.3–128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~ 5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Codacs™ Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency

This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation w...

متن کامل

In situ Probe Microphone Measurement for Testing the Direct Acoustical Cochlear Stimulator

Hypothesis: Acoustical measurements can be used for functional control of a direct acoustic cochlear stimulator (DACS). Background: The DACS is a recently released active hearing implant that works on the principle of a conventional piston prosthesis driven by the rod of an electromagnetic actuator. An inherent part of the DACS actuator is a thin titanium diaphragm that allows for movement of t...

متن کامل

Bimodal benefits in Mandarin-speaking cochlear implant users with contralateral residual acoustic hearing.

OBJECTIVE The present study aimed to measure bimodal benefits and probe their underlying mechanisms in Mandarin-speaking cochlear implant (CI) subjects who had contralateral residual acoustic hearing. DESIGN The subjects recognised words or phonemes from the Mandarin Lexical Neighborhood Test in noise at a 10-dB signal-to-noise ratio (SNR) with acoustic stimulation, electric stimulation or th...

متن کامل

Critical Review: Is ipsilaterally combined electro-acoustic stimulation an effective alternative to hearing aids or cochlear implants alone when treating individuals with severe to profound high-frequency hearing loss?

High-frequency sensorineural hearing impairments are among the most common configurations observed in the adult population. These impairments are more than often treated with acoustic amplification or cochlear implantation, both of which have benefits and pitfalls that need to be considered. This critical review will examine the effectiveness of ipsilaterally combined acoustic and electric hear...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015