Separation of a complex mixture of heparin-derived oligosaccharides using reversed-phase high-performance liquid chromatography.

نویسندگان

  • Charuwan Thanawiroon
  • Robert J Linhardt
چکیده

A reversed-phase ion-pairing high-performance liquid chromatography (RP-HPIPC) method for the separation of a complex mixture of heparin-derived oligosacchrides has been developed by a stepwise optimization of the mobile phase, in which the concentration of ion-pairing reagent, mobile phase pH, and acetonitrile concentration were varied. The resolution of more than 30 oligosaccharide components was obtained, under optimized conditions, in an analysis time of less than 30 min. This represents the first RP-HPLC method that can separate a complex mixture of both small and large sulfated oligosaccharides in a single chromatographic step. The heparin-derived oligosaccharides, in this mixture, can also be separated under a second set of RP-HPIPC conditions using a volatile ion-pairing reagent, tributylammonium acetate, to aid in the recovery of individual sulfated oligosaccharides. Moreover, it was possible to replace sodium chloride gradient, required for eluting highly sulfated oligosaccharides, with a fixed, low concentration of a volatile salt, ammonium acetate, by utilizing an acetonitrile gradient. This solvent system might make it possible to directly interface this RP-HPIPC separation with mass spectral analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Liquid chromatography/mass spectrometry sequencing approach for highly sulfated heparin-derived oligosaccharides.

Liquid chromatography/mass spectrometry (LC/MS) is applied to the analysis of complex mixtures of oligosaccharides obtained through the controlled, heparinase-catalyzed depolymerization of heparin. Reversed-phase ion-pairing chromatography, utilizing a volatile mobile phase, results in the high resolution separation of highly sulfated, heparin-derived oligosaccharides. Simultaneous detection by...

متن کامل

Reversed-phase Salt Assisted Liquid-liquid Extraction: A New Technique for Preconcentration and Determination of Crocin in Herbal Medicines by HPLC

A reversed-phase salt assisted liquid-liquid extraction (RP-SALLE) method was developed for the preconcentration and determination of trace crocin in herbal medicines by high-performance liquid chromatography (HPLC). In developed method, the roles of the aqueous and organic phases are inverted so that the analyte is extracted from the organic into the aqueous phase after salt addition and phase...

متن کامل

Separation of Sedative – Hypnotic Drugs with Mixed Micellar Liquid Chromatography

Separation of ten sedative- hypnotic drugs was performed by RP-HPLC using mixed micellar mobile phase. Effect of temperature, type and amount of organic modifier in mobile phase on efficiency (N) and asymmetry factor (B/A) showed that, the appropriate conditions for a good separation were 35°C and 7% (V/V) butanol in mobile phase.  Variations of selectivity factor versus butanol concent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1014 1-2  شماره 

صفحات  -

تاریخ انتشار 2003