Ultrasound heating is curvilinear in nature and varies between transducers from the same manufacturer.

نویسندگان

  • Timothy J Demchak
  • Stephen J Straub
  • Lennart D Johns
چکیده

CONTEXT Ultrasound heating rates are known to differ between various manufacturers; it is unknown whether this difference exists within a manufacturer. OBJECTIVE Determine if intramuscular heating differences exist between transducers from the same manufacturer. STUDY DESIGN 3 x 10 repeated measures. Independent variables were Transducer (A, B, and C) and Time (10-min time points during the treatment). SETTING Controlled laboratory. PARTICIPANTS Twelve volunteers (M = 4, F = 8; age: 23 +/- 4 years; calf-girth: 37.94 +/- 4.16 cm; calf-skinfold: 27 +/- 17 mm). INTERVENTION Three 10-min 1MHz continuous ultrasound treatments performed at an intensity of 1.2 W/cm2, over an area 2x transducer. MAIN OUTCOME MEASURES Calf temperature increase. RESULTS Heating curve generated for each transducer were significantly different (P = .034) but the overall temperature increases following 10 minutes of treatment were within 0.1 degree C (F = 1.023 P = .573). CONCLUSION Heating curves differ between transducers from the same manufacturer but peak heating at 10 minutes was similar.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound transducer shape has no effect on measurements of lumbar multifidus muscle size.

OBJECTIVE Evidence is currently lacking for guidance on ultrasound transducer configuration (shape) when imaging muscle to measure its size. This study compared measurements made of lumbar multifidus on images obtained using curvilinear and linear transducers. METHOD Fifteen asymptomatic males (aged 21-32 years) had their right lumbar multifidus imaged at L3. Two transverse images were taken ...

متن کامل

The relationship between EMG and change in thickness of transversus abdominis.

OBJECTIVE To investigate the relationship between changes in thickness and EMG activity in the transversus abdominis muscle of healthy subjects and the reliability of ultrasound measurements using different modes and transducers. DESIGN Convenience sampling. BACKGROUND Chronic low back pain is associated with transversus abdominis dysfunction but EMG studies of this muscle are restricted to...

متن کامل

Determination of Relationships between the Ultrasound Velocity and the Physical Properties of Bovine Cortical Bone Femur

Accurate measurements of physical characteristics of bone are essential for diagnosis, assessment of change following treatment, and therefore, indirectly, for evaluation of new forms of therapy. This is particularly true of osteoporosis and aging skeleton, in which fractures occur easily. Methods: In this study an ultrasonic system was set-up and calibrated on Plexiglas tubes of variable thick...

متن کامل

Impact Analysis of Variation in Geometrical Features on Intrinsic Characteristics of Capacitive Micro-machined Ultrasonic Transducers

Capacitive Micro-machined Ultrasonic Transducers (CMUTs) are the ultrasonic devices which produce better features in contrast to piezoelectric transducers. The intrinsic parameter of CMUT varies with the variation in geometrical dimension of the device. The cavity height and the radius of the CMUT with circular membrane is varied in the lumped parallel plate model for its impact on the paramete...

متن کامل

Performance of ultrasound based measurement of 3D displacement using a curvilinear probe for organ motion tracking.

Three-dimensional (3D) soft tissue tracking is of interest for monitoring organ motion during therapy. Our goal is to assess the tracking performance of a curvilinear 3D ultrasound probe in terms of the accuracy and precision of measured displacements. The first aim was to examine the depth dependence of the tracking performance. This is of interest because the spatial resolution varies with di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of sport rehabilitation

دوره 16 2  شماره 

صفحات  -

تاریخ انتشار 2007