Developing a readiness assessment tool for weaning patients under mechanical ventilation

نویسندگان

  • Alireza Irajpour
  • Mahnaz Khodaee
  • Ahmadreza Yazdannik
  • Saeed Abbasi
چکیده

BACKGROUND Mechanical ventilation is one of the major supportive interventions in intensive care units. Weaning the patients from mechanical ventilation and its related criteria are of great importance due to the related complications. As there is no comprehensive standard to allocate the time of weaning and due to lack of local research in this field, development of a comprehensive tool to measure patients' readiness for weaning from mechanical ventilation is essential. Therefore, the present study was conducted with an aim to develop a readiness assessment tool for weaning patients from mechanical ventilation. MATERIALS AND METHODS This was a qualitative study with Delphi multi-triangulation design. In the first stage, the related items were extracted from the textbook and through searching the databases. In the second stage, after primary development of the items and based on supervisors' indications, a questionnaire was made and used for assessment through Delphi methods. Twenty individuals, meeting the inclusion criteria, were selected through purposive sampling and their viewpoints concerning acceptability of the items were collected. In the third stage, the items with appropriateness over 70% were selected, and in the fourth stage, the final questionnaire was developed after a session with a panel of experts and supervisors. In the present study, in the first stage, the needed items were collected from various articles and books to provide items extraction. In stages two to four, manual calculation and investigation made by a panel of experts and the research team were adopted. RESULTS In the first stage, 100 articles and 51 related books were selected. In the second stage, 87 items were extracted from the articles and books and were sent as semi-open questions of assessment. In the third stage, 28 items with consensus >70% were extracted, and in the fourth stage, 26 items were selected by a panel of experts and the finalized questionnaire with the title "Persian Weaning Tool" (PWT) was developed in three domains: Respiration with 9 items, cardiovascular with 4 items, and other related factors with 13 items. CONCLUSIONS A three-domain questionnaire is the product of experts' consensus in the present study, which can be used to reduce the length of connection to mechanical ventilation and its complications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity and reliability of “Persian Weaning Tool” in mechanically ventilated patients

BACKGROUND "Persian Weaning Tool" (PWT) is the only specific, national protocol designed to assess patients' readiness for weaning from mechanical ventilation in Iran. This study was developed to determine the validity and reliability of this protocol. MATERIALS AND METHODS This is a psychometric study conducted on 31 patients connected to mechanical ventilation were ready from weaning accord...

متن کامل

Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery

Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...

متن کامل

Weaning older patients from long-term mechanical ventilation: a pilot study.

BACKGROUND As older persons in the intensive care unit increasingly require long-term mechanical ventilation, accurate indications of readiness for weaning from ventilatory support are needed to avoid premature extubation. OBJECTIVE To describe temporal changes in pulmonary and systemic variables in older adults receiving long-term mechanical ventilation. METHODS After 3 days of unsuccessfu...

متن کامل

Clinical review: The ABC of weaning failure - a structured approach

About 20% to 30% of patients are difficult to wean from invasive mechanical ventilation. The pathophysiology of difficult weaning is complex. Accordingly, determining the reason for difficult weaning and subsequently developing a treatment strategy require a dedicated clinician with in-depth knowledge of the pathophysiology of weaning failure. This review presents a structural framework ('ABCDE...

متن کامل

The effect of protocol of weaning from mechanical ventilation on gastrointestinal function in people undergoing coronary artery bypass graft surgery (CABG)

Abstract Aim. The aim of this study was to examine the effect of protocol of weaning from mechanical ventilation on the gastrointestinal function in people undergoing CABG. Background. The most common problems after cardiac surgery in the intensive care unit are change in vital signs, respiratory problems, unsuccessful separation from mechanical ventilation, and gastrointestinal problems. Due t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2014