Emergency placement of a self-expandable covered stent for carotid artery injury during trans-sphenoidal surgery.
نویسندگان
چکیده
A patient sustained internal carotid artery (ICA) injury during trans-sphenoidal surgery. Bleeding from the resultant pseudo-aneurysm was not fully controlled by surgical packing. Emergency endovascular deployment over the injured ICA segment of a self-expandable covered-stent ('Symbiot' stent), initially designed for use in coronary saphenous vein-graft, was successful in securing haemostasis.
منابع مشابه
Emergency reconstructive endovascular management of intraoperative complications involving the internal carotid artery from trans-sphenoidal surgery.
PURPOSE To report our experience with intraoperative complications involving the internal carotid artery (ICA) during trans-sphenoidal surgery and their outcome with reconstructive endovascular management. METHODS A retrospective review was conducted of patients with an ICA injury related to trans-sphenoidal surgery from 2000 to 2012. Demographic data, clinical charts, indications for treatme...
متن کاملSubclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis
Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...
متن کاملTreatment of iatrogenic internal carotid artery laceration and carotid cavernous fistula with endovascular stent-graft placement.
The risk of fatal injury of the internal carotid artery (ICA) and surrounding anatomy during transsphenoidal surgery for pituitary adenoma is the most severe potential complication associated with this particular approach. We present a case in which iatrogenic injury to a patient's ICA and resultant carotid cavernous fistula and massive hemorrhage was successfully managed with the emergency pla...
متن کاملBridge to surgery in patients with obstructive colorectal cancer Comparison of covered and uncovered stents.
AIM Placement of self-expandable metallic stent has been used for bridge to surgery in the treatment of colorectal obstruction. Our aim was to compare technical success and complication rates of covered and uncovered inserted stents in colorectal malignant obstruction patients. MATERIAL OF STUDY A series of 24 obstruction colorectal cancer patients were selected and included in the study for ...
متن کاملArterial bleeding during EUS-guided pseudocyst drainage stopped by placement of a covered self-expandable metal stent
BACKGROUND Hemorrhagic complications during EUS-guided pseudocyst drainage can occur, because the vessels on the internal wall of the pseudocyst might be compressed by the fluid and thus not visible on color Doppler or even power Doppler EUS. CASE PRESENTATION We report a case of an immediate internal spurting arterial bleeding precipitated during EUS-guided pseudocyst drainage which stopped ...