Metallosis-induced iliopsoas bursal cyst causing venous obstruction and lower-limb swelling after metal-on-metal THA.
نویسندگان
چکیده
The formation of iliopsoas bursal cystic lesions after total hip arthroplasty is an infrequently reported condition. This article describes an unusual complication of a current-generation metal-on-metal total hip arthroplasty.A woman presented with unilateral spontaneous lower-limb swelling that developed 5 years postoperatively. It occurred secondary to venous obstruction by a metallosis-induced iliopsoas bursal cyst associated with markedly elevated intralesional cobalt and chromium levels. Metal artifact reduction sequence magnetic resonance imaging showed that the bursal cyst was communicating with the hip joint and that it severely compressed the common femoral vein. Based on the findings of high local tissue metal ions and vertical cup positioning causing edge loading, the authors proposed an inflammatory reaction to metal debris that tracked into the iliopsoas bursa and formed a cyst. The patient underwent revision of the excessively vertical acetabular component and conversion to a ceramic-on-ceramic bearing interface, drainage of the bursal cyst, and synovectomy. No signs existed of local recurrence at 1-year follow-up.To the authors' knowledge, the occurrence of metallosis-induced iliopsoas bursitis with secondary pressure effects after contemporary metal-on-metal total hip arthroplasty has not been reported. When treating hip dysplasia, one must avoid maximizing cup-host bone contact at the risk of oververticalization. Iliopsoas bursal cystic lesions can lead to severe vascular compressive symptoms with no ominous radiographic findings. Physicians and orthopedic surgeons should be aware of the possibility of this complication in patients with unexplained unilateral lower-limb swelling.
منابع مشابه
A Rare Case of Femoral Neuropathy Associated with Ilio-Psoas Bursitis After 10 Years of Total Hip Arthroplasty
We describe a case of femoral nerve palsy caused due to non-infective large iliopsoas bursitis after 10 years of cementless ceramic-on-metal THA. Bursectomy and exploration of femoral nerve were done to relieve the compressive symptoms of femoral nerve. Patient neurological symptoms were recovered within six months. Iliopsoas bursitis after THA can lead to anterior hip pain, lump in inguinal ar...
متن کاملNoninflammatory pseudotumor simulating venous thrombosis after metal-on-metal hip resurfacing.
Metal-on-metal hip resurfacing has become a widespread procedure, especially in young, physically active patients. Pseudotumor is a new complication that can occur after hip resurfacing and metal-on-metal total hip arthroplasty (THA). This article presents a case of a 37-year-old woman who underwent metal-on-metal resurfacing of the left hip for symptomatic osteoarthritis. Twelve months followi...
متن کاملMetallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component
The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...
متن کاملPseudotumor from Metal-on-Metal Total Hip Arthroplasty Causing Unilateral Leg Edema: Case Presentation and Literature Review
Metal-on-metal (MoM) total hip arthroplasty (THA) can be associated with adverse metal reactions, including pseudotumors. This case report describes a 58-year-old female with an MoM THA-related pseudotumor that caused unilateral leg edema from compression of her external iliac vein. After thorough preoperative workup to rule out infection and deep vein thrombosis and consultation with a vascula...
متن کاملCombined Vascular and Orthopaedic Approach for a Pseudotumor Causing Deep Vein Thrombosis after Metal-on-Metal Hip Resurfacing Arthroplasty
Introduction. Metal-on-metal (MoM) hip resurfacings have been associated with a variety of complications resulting from adverse reaction to metal debris. Pseudotumors have rarely been reported to cause deep venous thrombosis (DVT). Study Design. A case report and a review of the literature. Case Presentation. A 75-year-old female who had left metal-on-metal hip resurfacing 6 years ago presented...
متن کاملذخیره در منابع من