Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography
نویسندگان
چکیده
PURPOSE The purpose of the study was to determine the extent of displacement of the pulmonary vein antrums resulting from the intrinsic motion of the heart using 4D cardiac dual-source computed tomography (DSCT). METHODS Ten consecutive female patients were enrolled in this prospective planning study. In breath-hold, a contrast-injected cardiac 4-dimensional (4D) computed tomography (CT) synchronized to the electrocardiogram was obtained using a prospective sequential acquisition method including the extreme phases of systole and diastole. Right and left atrial fibrillation target volumes (CTVR and CTVL) were defined, with each target volume containing the antral regions of the superior and inferior pulmonary veins. Four points of interest were used as surrogates for the right superior and inferior pulmonary vein antrum (RSPVA and RIPVA) and the left superior and inferior pulmonary vein antrum (LSPVA and LIPVA). On our 4D post-processing workstation (MIM Maestro™, MIM Software Inc.), maximum displacement of each point of interest from diastole to systole was measured in the mediolateral (ML), anteroposterior (AP), and superoinferior (SI) directions. RESULTS Median age of the enrolled patients was 60 years (range, 56-71 years). Within the CTVR, the mean displacements of the superior and inferior surrogates were 3 mm vs. 1 mm (p=0.002), 2 mm vs. 0 mm (p= 0.001), and 3 mm vs. 0 mm (p=0.00001), in the ML, AP, and SI directions, respectively. On the left, mean absolute displacements of the LSPVA vs. LIPVA were similar at 4 mm vs. 1 mm (p=0.0008), 2 mm vs. 0 mm (p= 0.001), and 3 mm vs. 1 mm (p=0.00001) in the ML, AP, and SI directions. CONCLUSION When isolated from breathing, cardiac contraction is associated with minimal inferior pulmonary veins motion and modest (1-6 mm) motion of the superior veins. Target deformation was thus of a magnitude similar or greater than target motion, limiting the potential gains of cardiac tracking. Optimal strategies for cardiac radiosurgery should thus either incorporate the generation of an internal target or cardiac gating. In either case, cardiac 4D DSCT would allow for personalized margin definition.
منابع مشابه
Deep Vein Thrombosis, Pulmonary Embolism and Related Factors in Patients with Traumatic Brain Injury
Background and Objective:Deep vein thrombosis and pulmonary embolism are fatal problems following brain trauma that, if left untreated, can dramatically increase mortality. Therefore, the present study aimed to evaluate deep vein thrombosis, pulmonary embolism and related factors in patients with traumatic brain injury. Materials and Methods:This cross-sectional study was performed on 38 patie...
متن کاملAssessment of the coronary venous system by using cardiac CT.
PURPOSE We aimed to investigate the coronary venous system and its variations by using dual source computed tomography (CT). MATERIALS AND METHODS Retrospective assessment was carried out on 339 patients who underwent coronary CT angiography using 128-slice dual source CT for suspected coronary artery disease. The examinations were performed according to routine imaging protocols used to eval...
متن کاملCardiac Metastasis of Breast Cancer: A Case Report
Breast cancer is one of the most common cancers in women. As we know, cardiac metastases occur rarely. In this study, a 40-year-old woman referred to the hospital due to severe pain in the right leg. She was diagnosed with deep vein thrombosis (DVT) and received treatment, but, after one month and a half she returned with severe pain, exacerbated shortness of breath, cramping pain, and chest pa...
متن کاملPulmonary venous anatomy imaging with low-dose, prospectively ECG-triggered, high-pitch 128-slice dual-source computed tomography.
BACKGROUND The efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual-source CT protocol, we aim to determine the radiation dose and image quality in patients undergoing pulmonary vein (PV) imaging. METHODS AND RESULTS In 94 patients (61±9 years; 71% male) who underwent 128-slice dual-source CT (pitch 3.4), radiation d...
متن کامل