Multicentre evaluation of the Boehringer Mannheim/Hitachi 911 Analysis System
نویسندگان
چکیده
The analytical performance and practicability of the Boehringer Mannheim (BM)/Hitachi 911 analysis system have been assessed in a multicentre evaluation, which involved six laboratories from European countries. Analytes commonly used in classical clinical chemistry were tested in a core programme, which mainly followed the ECCLS guidelines. In addition, a satellite programme covered other analytes, such as proteins, drugs and urine analytes. In total, the study comprised more than 100 000 data items collected over a three-month period. The evaluation was supported with 'Computer Aided Evaluation' (CAEv) and telecommunications.Acceptance criteria for the results were established at the beginning of the study. Nearly all of the analytes met the imprecision limits: within-run imprecision (as CVs) was 2% for enzyme and substrate assays, 1% for ISE methods and 5% for immunoassays; between-day imprecision was 3l% for enzyme and substrate assays, 2% for ISE methods and 10% for immunoassays.No relevant drift effects (systematic deviation >/= 3%) were observed over eight hours. The methods were linear over a wide range. Sample-related and reagent-dependent carry-over can be reduced to a negligible amount by integration of a softwarecontrolled wash-step.Endogenous interferences were found for creatinine (Jaffé method) and uric acid assays (caused by bilirubin), for creatine kinase, creatine kinase MB isoform and gamma-glutamyltransferase (caused by haemoglobin), and for immunoglobulin A (caused by lipaemia)Accuracy was checked by an interlaboratory survey, recovery studies in control materials and method comparison studies. The survey showed that, with the exception of cholesterol and iron in two laboratories, the recovery of analytes did not deviate by more than 5%. Sixty-six of the 77 method comparisons performed met the acceptance criteria. The deviations of the remaining 11 results could be explained by differences in either calibration, application or by the use of different methods.Practicability was assessed using a questionnaire which covered all of the important aspects of an analysis system in the clinical laboratory. Twelve groups of attributes out of 14 were rater higher for the BM/Hitachi 911 than for the present situation in the laboratories concerned. Especially high scores were given for the versatility group.The acceptance criteria for the analytical performance of the BM/Hitachi 911 analysis system were fulfilled in all laboratory segments with few exceptions. The practicability exceeded the requirements in most of the attributes. The results of the study confirmed the usefulness of the system as a consolidated workstation in small- to medium-sized clinical laboratories and in STAT laboratories, or as an instrument for special analytes like proteins and drugs, or for urinalysis in large laboratories.
منابع مشابه
A multicentre evaluation of the Boehringer Mannheim/Hitachi 704 analysis system.
The selective multitest Boehringer Mannheim/Hitachi 704 analysis system was examined according to the ECCLS guidelines in a multicentre evaluation involving four laboratories. Ten routine parameters, covering most of the application settings of the instrument, were measured in the respective laboratory at temperatures 25, 30 or 37 degrees C. The trial lasted four months and gave more than 40,00...
متن کاملEvaluation of a random access analyser: BM/Hitachi 911
The performance of Boehringer Mannheim's BM/Hitachi 911 was evaluated for three months. The mean coeffcient of variation (CV) of the within-run and between-run imprecision of the 16 analytes were less than 1.16% (range 0.47-2.38%) and 1.35% (range 0.62-2.93,%), respectively. A linearity study for the various assays covered clinically important levels. No relevant drift was observed during an ei...
متن کاملMulticentre evaluation of the Boehringer Mannheim/Hitachi 917 analysis system
The new selective access analysis system BM/Hitachi 917 was evaluated in an international multicentre study, mainly according to the ECCLS protocol for the evaluation of analysers in clinical chemistry. Forty-three different analytes, covering 56 different methods--enzymes, substrates, electrolytes, specific proteins, drugs and urine applications--were tested in seven European clinical chemistr...
متن کاملStandardization of a commercial (Boehringer Mannheim diagnostics) enzymic method for cholesterol.
The Laboratory Standardization Panel of the National Cholesterol Education Program recommends that cholesterol method accuracy ideally be within 3% of the true value determined by the Abell-Kendall Reference Method, a component of the National Reference System for Cholesterol. As one of the Abell-Kendall network laboratories established to facilitate cholesterol standardization, the approach we...
متن کاملEvaluation of the Hitachi 717 analyser
The selective multitest Boehringer Mannheim Hitachi 717 analyser was evaluated according to the guidelines of the Comisión de Instrumentación de la Sociedad Española de Química Clinica and the European Committee for Clinical Laboratory Standards. The evaluation was performed in two steps: examination of the analytical units and evaluation in routine operation.THE EVALUATION OF THE ANALYTICAL UN...