Spectral rhoZ-projection method for characterization of body fluids in computed tomography: ex vivo experiments.
نویسندگان
چکیده
RATIONALE AND OBJECTIVES The identification of body fluids in computed tomography poses a major diagnostic challenge. The chemical composition of body fluids deviates only slightly from water with very similar computed tomographic (CT) values, which typically range from 0 to 100 HU. The aim of this study was to assess physical and chemical properties of different body fluids in an ex vivo setting. MATERIALS AND METHODS A total of 44 samples of blood, blood mixed with pus, pus, bile, and urine obtained during diagnostic and therapeutic punctures were scanned at 80 and 140 kV. Data was quantitatively assessed using the spectral rhoZ-projection algorithm, which converts dual-energy CT scans into mass density (rho) and effective atomic number (Z(eff.)) information. RESULTS Attenuation values measured at 80 and 140 kV were largely overlapping. CT values allowed, to some degree, for the differentiation of bile or pus from blood or the blood/pus mixture. By applying the rhoZ-projection, most substances, except for urine, were distinguishable with only small standard deviations ranging between 0.003 and 0.007 g/cm(3) for mass density and between 0.020 and 0.043 for Z(eff.). CONCLUSION The rhoZ-projection method is suited to quantitatively assess mass density and effective atomic number of ex vivo body fluid samples. In clinical routine, this technique might be useful for identifying unclear fluid collections even in unenhanced computed tomography.
منابع مشابه
Correction to: An Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography
Correction to: An Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography Abbas Mesgarani1, Azadeh Zakariaie2, Azam Haddadi Kohsar1, Sina Haghanifar3, Jamshid Yazdani Charati4, Arman Ebrahimi5 1 Assistant Professor, Department of Endodontics, Faculty of Dentistry, Mazandaran University of Medical S...
متن کاملAn Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography
Background and purpose: The purpose of mechanical cleaning of the root canal is to clean the canal walls, create a conical shape to facilitate access, effective washing, and filling all areas of the root canal. Errors such as root canal transportation are cuased by excessive dentin removal from the canal. The objective of this study was to investigate root canal transportation by a BT Race rota...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Academic radiology
دوره 16 6 شماره
صفحات -
تاریخ انتشار 2009