Cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures.

نویسندگان

  • K X Michalakis
  • A L Pissiotis
  • H Hirayama
چکیده

The major disadvantage of cement-retained implant-supported fixed partial dentures (FPDs) is difficulty in retrievability. The retentive strengths of the provisional luting agents usually employed in these cases are therefore an important consideration. This study evaluated the cement failure loads of 4 provisional luting agents used for the cementation of FPDs supported by 2 implants or 4 implants. Nogenol luting agent exhibited the lowest retentive values in both types of FPD. ImProv proved to be the most retentive cement of all tested. Temp Bond NE and Temp Bond presented significantly different values (P < .05) for the 2-implant FPD, but not for the 4-implant model. On the basis of the study results, it may be concluded that Nogenol appears to be more appropriate for cementation of both 2- and 4-implant-supported FPDs when removal of the provisionally cemented superstructure is anticipated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of luting agents on the retention of dental implant-supported crowns.

BACKGROUND This study was designed to evaluate the retentive strength of 7 different luting agents on cement-retained implant abutment/analog assemblies. METHODS Fifty-six Steri-Oss implant abutment/analog assemblies and cast superstructures were randomly divided into 7 groups: definitive cements included zinc phosphate cement, Advance, All-Bond 2, Panavia F, and Durelon, while provisional ce...

متن کامل

Post Cementation Sensitivity in Vital Abutments of Metal-ceramic Fixed Partial Dentures

This randomized clinical trial was carried out to compare post cementation sensitivity in vital abutments of metal-ceramic fixed partial dentures using glass ionomer luting cement and resin based luting cement. It analyzed the results of 182 patients whose records were completed during study duration of 09 months at Department of Prosthodontics, AFID, Rawalpindi. Cold sensitivity tests were use...

متن کامل

Comparison of uniaxial resistance forces of cements used with implant-supported crowns.

PURPOSE Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations. While the functional life spans of these cements are unpredictable, the relative retentiveness of various permanent and provisional cements between dental alloys and titanium abutments is not well documented. The aim of this study was to compare the uniaxial resistance force...

متن کامل

Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures

Implant-supported dental prostheses can be retained by a screw or cement. Implant-supported fixed partial dentures have a passive fit. A passive fit means there is an internal gap between the abutment surface and the intaglio of the retainer to insure that there is no lateral pressure on the supporting implants or friction upon seating of the prosthesis. This gap is filled with cement for reten...

متن کامل

In Vitro Fit and Cementation Resistance of Provisional Crowns for Single Implant-Supported Restorations.

This study aimed to verify marginal fit and the effect of cement film thickness standardization on retention of provisional crowns made with prefabricated acrylic cylinders on abutments, using two temporary luting agents subjected or not to mechanical cycling. Provisional crowns were made from bis-acryl (Luxatemp Fluorescence) or methyl methacrylate (Duralay) resins on acrylic cylinders and mar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2000