Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs.

نویسندگان

  • R H Warren
  • J E Fewell
  • S H Alderson
چکیده

Respiratory inductive plethysmography (RIP) can measure breathing patterns noninvasively. Calibration is required for rib cage and abdomen transducers utilizing breaths with different compartment contribution correlated with tidal volume measured by integrated pneumotachography (PNT). This study was performed to determine if RIP remains accurate during sleep states following calibration in the quietly awake state. We used our single position graphic calibration technique (SPG) to calculate gain factors in seven tracheostomized lambs. Validation of gain factors was accomplished by comparing tidal volume obtained simultaneously by RIP and PNT during quiet wakefulness (QW), quiet sleep (QS) and active sleep (AS). Results of the study showed that RIP was accurately calibrated during QW. Accuracy was decreased during QS and AS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of breath size and posture on calibration of the respiratory inductive plethysmograph by multiple linear regression.

The accuracy of the respiratory inductive plethysmograph (Respitrace) for estimation of lung volume changes during quiet breathing and vital capacity (VC) manoeuvres was evaluated using a variant of the multiple linear regression (MLR) technique. We applied this technique successively on quiet breathing, on the whole VC, and on each of the four quarters of the VC separately. This was carried ou...

متن کامل

Importance of breath size in calibrating the respiratory inductive plethysmograph.

The usual method of calibrating the respiratory inductive plethysmograph (RIP) is to have the subject breathe over a rather narrow volume range, either resting tidal volume or into a bag containing a fixed larger volume, in both the standing and supine positions. During a previous study in our laboratory using the RIP to quantify ventilation during sleep in young and elderly adults, we began to...

متن کامل

Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration.

BACKGROUND Portable respiratory inductive plethysmography (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position. OBJECTIVES To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment of RIP calibration using position sensor f...

متن کامل

Review and Comparison of In-field Calibration Methods of Accelerometer Based on Gravity Vector

Considering the wide applications of accelerometers to determine position and attitude and due to reducing of accuracy of this sensors because of some errors, this paper discusses the calibration of accelerometers. Also because the traditional calibration methods are very time consuming, costly and need precision laboratory equipment, in-field calibration methods are recommended which are simpl...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 94 2  شماره 

صفحات  -

تاریخ انتشار 1988